CVE-2018-0022
Vulnérabilité non évaluée dans Junos OS (Juniper Networks)
Description
A Junos device with VPLS routing-instances configured on one or more interfaces may be susceptible to an mbuf leak when processing a specific MPLS packet. Approximately 1 mbuf is leaked per each packet processed. The number of mbufs is platform dependent. The following command provides the number of mbufs that are currently in use and maximum number of mbufs that can be allocated on a platform: > show system buffers 2437/3143/5580 mbufs in use (current/cache/total) Once the device runs out of mbufs it will become inaccessible and a restart will be required. This issue only affects end devices, transit devices are not affected. Affected releases are Juniper Networks Junos OS with VPLS configured running: 12.1X46 versions prior to 12.1X46-D76; 12.3X48 versions prior to 12.3X48-D66, 12.3X48-D70; 14.1 versions prior to 14.1R9; 14.1X53 versions prior to 14.1X53-D47; 14.2 versions prior to 14.2R8; 15.1 versions prior to 15.1F2-S19, 15.1F6-S10, 15.1R4-S9, 15.1R5-S7, 15.1R6-S4, 15.1R7; 15.1X49 versions prior to 15.1X49-D131, 15.1X49-D140; 15.1X53 versions prior to 15.1X53-D58 on EX2300/EX3400; 15.1X53 versions prior to 15.1X53-D233 on QFX5200/QFX5110; 15.1X53 versions prior to 15.1X53-D471 on NFX; 15.1X53 versions prior to 15.1X53-D66 on QFX10; 16.1 versions prior to 16.1R3-S8, 16.1R4-S6, 16.1R5; 16.2 versions prior to 16.2R1-S6, 16.2R2-S5, 16.2R3; 17.1 versions prior to 17.1R1-S7, 17.1R2-S6, 17.1R3; 17.2 versions prior to 17.2R1-S5, 17.2R2.
Gravité et risque d'exploitation
CVE-2018-0022 obtient un score CVSS de 0.0/10, soit une gravité non évaluée. Selon le modèle EPSS, la probabilité qu'elle soit exploitée dans les 30 prochains jours est de 2.25 %, ce qui la place devant 82.6 % des CVE référencées.
Que faire ?
- Vérifiez si Junos OS (versions <12.3X48-D66, 12.3X48-D70, 16.1, 15.1X49, <17.2R1-S5, 17.2R2, 14.1X53, 14.1, <16.1R3-S8, 16.1R4-S6, 16.1R5, <15.1F2-S19, 15.1F6-S10, 15.1R4-S9, 15.1R5-S7, 15.1R6-S4, 15.1R7, 16.2, <14.1R9, <14.2R8, <15.1X53-D233, <17.1R1-S7, 17.1R2-S6, 17.1R3, <16.2R1-S6, 16.2R2-S5, 16.2R3, 15.1, <15.1X53-D471, 17.1, <12.1X46-D76, 15.1X53, 17.2, <15.1X53-D58, <15.1X49-D131, 15.1X49-D140, 12.3X48, <15.1X53-D66, <14.1X53-D47, 14.2, 12.1X46) est présent sur votre parc.
- Appliquez le correctif ou la version corrigée indiqués dans les références de l'éditeur.
- À défaut de correctif, limitez l'exposition (filtrage réseau, désactivation du composant).
- Automatisez la détection : les agents CVE Heimdall (gratuits, open source) corrèlent l'inventaire de vos serveurs avec la base CVE.