Description

An issue was discovered in myStrom WiFi Switch V1 before 2.66, WiFi Switch V2 before 3.80, WiFi Switch EU before 3.80, WiFi Bulb before 2.58, WiFi LED Strip before 3.80, WiFi Button before 2.73, and WiFi Button Plus before 2.73. The SSL/TLS server certificate in the device to cloud communication was not verified by the device. As a result, an attacker in control of the network traffic of a device could have taken control of a device by intercepting and modifying commands issued from the server to the device in a Man-in-the-Middle attack. This included the ability to inject firmware update commands into the communication and cause the device to install maliciously modified firmware.

Gravité et risque d'exploitation

CVE-2018-15476 obtient un score CVSS de 0.0/10, soit une gravité non évaluée. Selon le modèle EPSS, la probabilité qu'elle soit exploitée dans les 30 prochains jours est de 0.76 %, ce qui la place devant 54.3 % des CVE référencées.

Que faire ?

  • Vérifiez si le produit concerné est présent sur votre parc.
  • Appliquez le correctif ou la version corrigée indiqués dans les références de l'éditeur.
  • À défaut de correctif, limitez l'exposition (filtrage réseau, désactivation du composant).
  • Automatisez la détection : les agents CVE Heimdall (gratuits, open source) corrèlent l'inventaire de vos serveurs avec la base CVE.