CVE-2018-4858

Vulnérabilité non évaluée dans IEC 61850 system configurator, DIGSI 5 (affected as IEC 61850 system configurator is incorporated), DIGSI 4, SICAM PAS/PQS, SICAM PQ Analyzer, SICAM SCC (Siemens AG)

CVSS 0.0 · Non évaluée
EPSS 1.8%
Siemens AG•IEC 61850 system configurator, DIGSI 5 (affected as IEC 61850 system configurator is incorporated), DIGSI 4, SICAM PAS/PQS, SICAM PQ Analyzer, SICAM SCC•Versions : IEC 61850 system configurator : All versions < V5.80, DIGSI 4 : All versions < V4.93, SICAM PAS/PQS : All versions < V8.11, SICAM SCC : All versions < V9.02 HF3, SICAM PQ Analyzer : All versions < V3.11, DIGSI 5 (affected as IEC 61850 system configurator is incorporated) : All versions < V7.80

Description

A vulnerability has been identified in IEC 61850 system configurator (All versions < V5.80), DIGSI 5 (affected as IEC 61850 system configurator is incorporated) (All versions < V7.80), DIGSI 4 (All versions < V4.93), SICAM PAS/PQS (All versions < V8.11), SICAM PQ Analyzer (All versions < V3.11), SICAM SCC (All versions < V9.02 HF3). A service of the affected products listening on all of the host's network interfaces on either port 4884/TCP, 5885/TCP, or port 5886/TCP could allow an attacker to either exfiltrate limited data from the system or to execute code with Microsoft Windows user permissions. Successful exploitation requires an attacker to be able to send a specially crafted network request to the vulnerable service and a user interacting with the service's client application on the host. In order to execute arbitrary code with Microsoft Windows user permissions, an attacker must be able to plant the code in advance on the host by other means. The vulnerability has limited impact to confidentiality and integrity of the affected system. At the time of advisory publication no public exploitation of this security vulnerability was known. Siemens confirms the security vulnerability and provides mitigations to resolve the security issue.

Gravité et risque d'exploitation

CVE-2018-4858 obtient un score CVSS de 0.0/10, soit une gravité non évaluée. Selon le modèle EPSS, la probabilité qu'elle soit exploitée dans les 30 prochains jours est de 1.81 %, ce qui la place devant 78.2 % des CVE référencées.

Que faire ?

  • Vérifiez si IEC 61850 system configurator, DIGSI 5 (affected as IEC 61850 system configurator is incorporated), DIGSI 4, SICAM PAS/PQS, SICAM PQ Analyzer, SICAM SCC (versions IEC 61850 system configurator : All versions < V5.80, DIGSI 4 : All versions < V4.93, SICAM PAS/PQS : All versions < V8.11, SICAM SCC : All versions < V9.02 HF3, SICAM PQ Analyzer : All versions < V3.11, DIGSI 5 (affected as IEC 61850 system configurator is incorporated) : All versions < V7.80) est présent sur votre parc.
  • Appliquez le correctif ou la version corrigée indiqués dans les références de l'éditeur.
  • À défaut de correctif, limitez l'exposition (filtrage réseau, désactivation du composant).
  • Automatisez la détection : les agents CVE Heimdall (gratuits, open source) corrèlent l'inventaire de vos serveurs avec la base CVE.