CVE-2019-10918

Vulnérabilité non évaluée dans SIMATIC PCS 7 V8.0 and earlier (Siemens AG)

CVSS 0.0 · Non évaluée
EPSS 1.9%
Siemens AG•SIMATIC PCS 7 V8.0 and earlier•Versions : All versions < V14.1 Upd 8, All versions < V15.1 Upd 3, All versions < V9.0 SP2 with WinCC V7.4 SP1 Upd11, All versions < V8.2 SP1 with WinCC V7.4 SP1 Upd11, All versions < V7.5 Upd 3, All versions < V14 SP1 Upd 9, All versions < V8.1 with WinCC V7.3 Upd 19, All versions, All versions < V7.4 SP1 Upd 11, All versions < V7.3 Upd 19

Description

A vulnerability has been identified in SIMATIC PCS 7 V8.0 and earlier (All versions), SIMATIC PCS 7 V8.1 (All versions < V8.1 with WinCC V7.3 Upd 19), SIMATIC PCS 7 V8.2 (All versions < V8.2 SP1 with WinCC V7.4 SP1 Upd11), SIMATIC PCS 7 V9.0 (All versions < V9.0 SP2 with WinCC V7.4 SP1 Upd11), SIMATIC WinCC (TIA Portal) V13 (All versions), SIMATIC WinCC (TIA Portal) V14 (All versions < V14 SP1 Upd 9), SIMATIC WinCC (TIA Portal) V15 (All versions < V15.1 Upd 3), SIMATIC WinCC Runtime Professional V13 (All versions), SIMATIC WinCC Runtime Professional V14 (All versions < V14.1 Upd 8), SIMATIC WinCC Runtime Professional V15 (All versions < V15.1 Upd 3), SIMATIC WinCC V7.2 and earlier (All versions), SIMATIC WinCC V7.3 (All versions < V7.3 Upd 19), SIMATIC WinCC V7.4 (All versions < V7.4 SP1 Upd 11), SIMATIC WinCC V7.5 (All versions < V7.5 Upd 3). An authenticatd attacker with network access to the DCOM interface could execute arbitrary commands with SYSTEM privileges. The vulnerability could be exploited by an attacker with network access to the affected system. Successful exploitation requires authentication with a low-privileged user account and no user interaction. An attacker could use the vulnerability to compromise confidentiality and integrity and availability of the affected system. At the time of advisory publication no public exploitation of this security vulnerability was known.

Gravité et risque d'exploitation

CVE-2019-10918 obtient un score CVSS de 0.0/10, soit une gravité non évaluée. Selon le modèle EPSS, la probabilité qu'elle soit exploitée dans les 30 prochains jours est de 1.93 %, ce qui la place devant 79.6 % des CVE référencées.

Que faire ?

  • Vérifiez si SIMATIC PCS 7 V8.0 and earlier (versions All versions < V14.1 Upd 8, All versions < V15.1 Upd 3, All versions < V9.0 SP2 with WinCC V7.4 SP1 Upd11, All versions < V8.2 SP1 with WinCC V7.4 SP1 Upd11, All versions < V7.5 Upd 3, All versions < V14 SP1 Upd 9, All versions < V8.1 with WinCC V7.3 Upd 19, All versions, All versions < V7.4 SP1 Upd 11, All versions < V7.3 Upd 19) est présent sur votre parc.
  • Appliquez le correctif ou la version corrigée indiqués dans les références de l'éditeur.
  • À défaut de correctif, limitez l'exposition (filtrage réseau, désactivation du composant).
  • Automatisez la détection : les agents CVE Heimdall (gratuits, open source) corrèlent l'inventaire de vos serveurs avec la base CVE.

Références