CVE-2019-1599

Vulnérabilité non évaluée dans Nexus 1000V Switch for Microsoft Hyper-V (Cisco)

CVSS 0.0 · Non évaluée
EPSS 14.3%
Cisco•Nexus 1000V Switch for Microsoft Hyper-V•Versions : <6.2(22), <8.3(2), <4.0(2a), <7.1(5)N1(1b), <7.0(3)I7(6), <5.2(1)SM3(2.1), <7.3(3)D1(1), <8.2(3), <6.0(2)A8(11), <7.0(3)F3(5), <9.2(2), <3.2(3j), <5.2(1)SV3(4.1a), <7.3(5)N1(1)

Description

A vulnerability in the network stack of Cisco NX-OS Software could allow an unauthenticated, remote attacker to cause a denial of service (DoS) condition on the affected device. The vulnerability is due to an issue with allocating and freeing memory buffers in the network stack. An attacker could exploit this vulnerability by sending crafted TCP streams to an affected device in a sustained way. A successful exploit could cause the network stack of an affected device to run out of available buffers, impairing operations of control plane and management plane protocols, resulting in a DoS condition. Note: This vulnerability can be triggered only by traffic that is destined to an affected device and cannot be exploited using traffic that transits an affected device. Nexus 1000V Switch for Microsoft Hyper-V is affected in versions prior to 5.2(1)SM3(2.1). Nexus 1000V Switch for VMware vSphere is affected in versions prior to 5.2(1)SV3(4.1a). Nexus 3000 Series Switches are affected in versions prior to 7.0(3)I7(6) and 9.2(2). Nexus 3500 Platform Switches are affected in versions prior to 6.0(2)A8(11), 7.0(3)I7(6), and 9.2(2). Nexus 3600 Platform Switches are affected in versions prior to 7.0(3)F3(5) and 9.2(2). Nexus 5500, 5600, and 6000 Series Switches are affected in versions prior to 7.1(5)N1(1b) and 7.3(5)N1(1). Nexus 7000 and 7700 Series Switches are affected in versions prior to 6.2(22. Nexus 9500 R-Series Line Cards and Fabric Modules are affected in versions prior to 7.0(3)F3(5) and 9.2(2). UCS 6200 and 6300 Series Fabric Interconnect are affected in versions prior to 3.2(3j) and 4.0(2a). UCS 6400 Series Fabric Interconnect are affected in versions prior to 4.0(2a).

Gravité et risque d'exploitation

CVE-2019-1599 obtient un score CVSS de 0.0/10, soit une gravité non évaluée. Selon le modèle EPSS, la probabilité qu'elle soit exploitée dans les 30 prochains jours est de 14.28 %, ce qui la place devant 96.6 % des CVE référencées.

Que faire ?

  • Vérifiez si Nexus 1000V Switch for Microsoft Hyper-V (versions <6.2(22), <8.3(2), <4.0(2a), <7.1(5)N1(1b), <7.0(3)I7(6), <5.2(1)SM3(2.1), <7.3(3)D1(1), <8.2(3), <6.0(2)A8(11), <7.0(3)F3(5), <9.2(2), <3.2(3j), <5.2(1)SV3(4.1a), <7.3(5)N1(1)) est présent sur votre parc.
  • Appliquez le correctif ou la version corrigée indiqués dans les références de l'éditeur.
  • À défaut de correctif, limitez l'exposition (filtrage réseau, désactivation du composant).
  • Automatisez la détection : les agents CVE Heimdall (gratuits, open source) corrèlent l'inventaire de vos serveurs avec la base CVE.

Références