CVE-2020-1601

Vulnérabilité moyenne dans Junos OS (Juniper Networks)

CVSS 5.3 · Moyenne
EPSS 1.1%
Juniper Networks•Junos OS•Versions : <17.2R1-S9, 17.2R3-S2, <18.2R2-S6, 18.3R2, 16.1, <17.1R2-S11, 17.1R3, 15.1X49, <18.4R1-S2, 18.4R2, <17.4R2-S2, 17.4R3, 16.2, 18.2, <18.1R3-S2, <15.1X53-D238, 15.1X53-D496, 15.1X53-D592, 18.3, 15.1, <18.2X75-D40, 17.1, <15.1F6-S13, 15.1R7-S4, <16.2R2-S9, 17.4, 18.1, 18.4, 15.1X53, 17.3, <15.1X49-D180, 18.2X75, <17.3R3-S3, <18.2R3, 17.2, <16.1R7-S4

Description

Certain types of malformed Path Computation Element Protocol (PCEP) packets when received and processed by a Juniper Networks Junos OS device serving as a Path Computation Client (PCC) in a PCEP environment using Juniper's path computational element protocol daemon (pccd) process allows an attacker to cause the pccd process to crash and generate a core file thereby causing a Denial of Service (DoS). Continued receipt of this family of malformed PCEP packets will cause an extended Denial of Service (DoS) condition. This issue affects: Juniper Networks Junos OS: 15.1 versions prior to 15.1F6-S13, 15.1R7-S4; 15.1X49 versions prior to 15.1X49-D180 on SRX Series; 15.1X53 versions prior to 15.1X53-D238, 15.1X53-D496, 15.1X53-D592; 16.1 versions prior to 16.1R7-S4; 16.2 versions prior to 16.2R2-S9; 17.1 versions prior to 17.1R2-S11, 17.1R3; 17.2 versions prior to 17.2R1-S9; 17.2 version 17.2R2 and later prior to 17.2R3-S2; 17.3 versions prior to 17.3R3-S3; 17.4 versions prior to 17.4R2-S2, 17.4R3; 18.1 versions prior to 18.1R3-S2; 18.2 versions prior to 18.2R2-S6, 18.2R3; 18.2X75 versions prior to 18.2X75-D40; 18.3 versions prior to 18.3R2; 18.4 versions prior to 18.4R1-S2, 18.4R2. This issue does not affect releases of Junos OS prior to 15.1R1.

Gravité et risque d'exploitation

CVE-2020-1601 obtient un score CVSS de 5.3/10, soit une gravité moyenne. Selon le modèle EPSS, la probabilité qu'elle soit exploitée dans les 30 prochains jours est de 1.07 %, ce qui la place devant 64.5 % des CVE référencées.

Que faire ?

  • Vérifiez si Junos OS (versions <17.2R1-S9, 17.2R3-S2, <18.2R2-S6, 18.3R2, 16.1, <17.1R2-S11, 17.1R3, 15.1X49, <18.4R1-S2, 18.4R2, <17.4R2-S2, 17.4R3, 16.2, 18.2, <18.1R3-S2, <15.1X53-D238, 15.1X53-D496, 15.1X53-D592, 18.3, 15.1, <18.2X75-D40, 17.1, <15.1F6-S13, 15.1R7-S4, <16.2R2-S9, 17.4, 18.1, 18.4, 15.1X53, 17.3, <15.1X49-D180, 18.2X75, <17.3R3-S3, <18.2R3, 17.2, <16.1R7-S4) est présent sur votre parc.
  • Appliquez le correctif ou la version corrigée indiqués dans les références de l'éditeur.
  • À défaut de correctif, limitez l'exposition (filtrage réseau, désactivation du composant).
  • Automatisez la détection : les agents CVE Heimdall (gratuits, open source) corrèlent l'inventaire de vos serveurs avec la base CVE.

Références