CVE-2020-1643
Vulnérabilité moyenne dans Junos OS (Juniper Networks)
Description
Execution of the "show ospf interface extensive" or "show ospf interface detail" CLI commands on a Juniper Networks device running Junos OS may cause the routing protocols process (RPD) to crash and restart if OSPF interface authentication is configured, leading to a Denial of Service (DoS). By continuously executing the same CLI commands, a local attacker can repeatedly crash the RPD process causing a sustained Denial of Service. Note: Only systems utilizing ARM processors, found on the EX2300 and EX3400, are vulnerable to this issue. Systems shipped with other processor architectures are not vulnerable to this issue. The processor architecture can be displayed via the 'uname -a' command. For example: ARM (vulnerable): % uname -a | awk '{print $NF}' arm PowerPC (not vulnerable): % uname -a | awk '{print $NF}' powerpc AMD (not vulnerable): % uname -a | awk '{print $NF}' amd64 Intel (not vulnerable): % uname -a | awk '{print $NF}' i386 This issue affects Juniper Networks Junos OS: 12.3X48 versions prior to 12.3X48-D100; 14.1X53 versions prior to 14.1X53-D140, 14.1X53-D54; 15.1 versions prior to 15.1R7-S7; 15.1X49 versions prior to 15.1X49-D210; 15.1X53 versions prior to 15.1X53-D593; 16.1 versions prior to 16.1R7-S8; 17.1 versions prior to 17.1R2-S12; 17.2 versions prior to 17.2R3-S4; 17.3 versions prior to 17.3R3-S8; 17.4 versions prior to 17.4R2-S2, 17.4R3; 18.1 versions prior to 18.1R3-S2; 18.2 versions prior to 18.2R2, 18.2R3; 18.2X75 versions prior to 18.2X75-D40; 18.3 versions prior to 18.3R1-S2, 18.3R2.
Gravité et risque d'exploitation
CVE-2020-1643 obtient un score CVSS de 5.5/10, soit une gravité moyenne. Selon le modèle EPSS, la probabilité qu'elle soit exploitée dans les 30 prochains jours est de 0.35 %, ce qui la place devant 27.7 % des CVE référencées.
Que faire ?
- Vérifiez si Junos OS (versions 16.1, 15.1X49, <17.4R2-S2, 17.4R3, 14.1X53, 18.2, <18.1R3-S2, <12.3X48-D100, <18.3R1-S2, 18.3R2, 18.3, <16.1R7-S8, 15.1, <18.2X75-D40, 17.1, <15.1R7-S7, 18.1, 17.4, <18.2R2, 18.2R3, 15.1X53, 17.3, <17.3R3-S8, <17.2R3-S4, <15.1X53-D593, 18.2X75, <17.1R2-S12, <14.1X53-D140, 14.1X53-D54, 12.3X48, <15.1X49-D210, 17.2) est présent sur votre parc.
- Appliquez le correctif ou la version corrigée indiqués dans les références de l'éditeur.
- À défaut de correctif, limitez l'exposition (filtrage réseau, désactivation du composant).
- Automatisez la détection : les agents CVE Heimdall (gratuits, open source) corrèlent l'inventaire de vos serveurs avec la base CVE.
