An Exposure of Sensitive Information to an Unauthorized Actor vulnerability in the PFE of Juniper Networks Junos OS on PTX Series and QFX10k Series allows an adjacent unauthenticated attacker to gain access to sensitive information. PTX1000 and PTX10000 Series, and QFX10000 Series and PTX5000 Series devices sometimes do not reliably pad Ethernet packets, and thus some packets can contain fragments of system memory or data from previous packets. This issue is also known as 'Etherleak' and often detected as CVE-2003-0001. This issue affects: Juniper Networks Junos OS on PTX1000 and PTX10000 Series: All versions prior to 18.4R3-S11; 19.1 versions prior to 19.1R2-S3, 19.1R3-S7; 19.2 versions prior to 19.2R1-S8, 19.2R3-S4; 19.3 versions prior to 19.3R3-S4; 19.4 versions prior to 19.4R2-S5, 19.4R3-S6; 20.1 versions prior to 20.1R3-S2; 20.2 versions prior to 20.2R3-S3; 20.3 versions prior to 20.3R3-S2; 20.4 versions prior to 20.4R3-S4; 21.1 versions prior to 21.1R2-S1, 21.1R3; 21.2 versions prior to 21.2R1-S1, 21.2R2. Juniper Networks Junos OS on QFX10000 Series and PTX5000 Series: All versions prior to 18.3R3-S6; 18.4 versions prior to 18.4R2-S9, 18.4R3-S10; 19.1 versions prior to 19.1R2-S3, 19.1R3-S7; 19.2 versions prior to 19.2R1-S8, 19.2R3-S4; 19.3 versions prior to 19.3R3-S4; 19.4 versions prior to 19.4R2-S6, 19.4R3-S6; 20.1 versions prior to 20.1R3-S2; 20.2 versions prior to 20.2R3-S3; 20.3 versions prior to 20.3R3-S1; 20.4 versions prior to 20.4R3-S1; 21.1 versions prior to 21.1R2-S1, 21.1R3; 21.2 versions prior to 21.2R2.
Gravité et risque d'exploitation
CVE-2022-22216 obtient un score CVSS de 4.3/10, soit une gravité moyenne. Selon le modèle EPSS, la probabilité qu'elle soit exploitée dans les 30 prochains jours est de 0.30 %, ce qui la place devant 21.4 % des CVE référencées.
Que faire ?
- Vérifiez si Junos OS (versions <19.2R1-S8, 19.2R3-S4, <20.1R3-S2, 19.2, <21.1R2-S1, 21.1R3, 19.3, 20.1, <20.3R3-S1, <21.2R2, <18.4R2-S9, 18.4R3-S10, 21.2, 20.3, 19.1, 20.4, <20.4R3-S4, <20.2R3-S3, <18.4R3-S11, 21.1, 18.4, 19.4, <19.4R2-S6, 19.4R3-S6, <18.3R3-S6, <20.3R3-S2, 20.2, <20.4R3-S1, <21.2R1-S1, 21.2R2, <19.1R2-S3, 19.1R3-S7, <19.3R3-S4, <19.4R2-S5, 19.4R3-S6) est présent sur votre parc.
- Appliquez le correctif ou la version corrigée indiqués dans les références de l'éditeur.
- À défaut de correctif, limitez l'exposition (filtrage réseau, désactivation du composant).
- Automatisez la détection : les agents CVE Heimdall (gratuits, open source) corrèlent l'inventaire de vos serveurs avec la base CVE.