CVE-2022-50552

Vulnérabilité non évaluée dans Linux (Linux)

CVSS 0.0 · Non évaluée
EPSS 0.2%
Linux•Linux•Versions : <c478b3b2900f1834cf9eda5bfef0d5696099505d, 0, 4.19, <9646443f28f33ec545ae303e613c3f476fad4dc1, 5.15.209, <=5.10.*, d48ece209f82c9ce07be942441b53d3fa3664936, <=6.0.*, 6.1, 5.10.258, 5.19.17, <4.19, <=*, <63a681bcc32a43528ce0f690569f7f48e59c3963, <=5.15.*, <0f90015383cd3f1128bebfbe7a97122d97808046, <8237c01f1696bc53c470493bf1fe092a107648a6, 6.0.3, <=5.19.*

Description

In the Linux kernel, the following vulnerability has been resolved: blk-mq: use quiesced elevator switch when reinitializing queues The hctx's run_work may be racing with the elevator switch when reinitializing hardware queues. The queue is merely frozen in this context, but that only prevents requests from allocating and doesn't stop the hctx work from running. The work may get an elevator pointer that's being torn down, and can result in use-after-free errors and kernel panics (example below). Use the quiesced elevator switch instead, and make the previous one static since it is now only used locally. nvme nvme0: resetting controller nvme nvme0: 32/0/0 default/read/poll queues BUG: kernel NULL pointer dereference, address: 0000000000000008 #PF: supervisor read access in kernel mode #PF: error_code(0x0000) - not-present page PGD 80000020c8861067 P4D 80000020c8861067 PUD 250f8c8067 PMD 0 Oops: 0000 [#1] SMP PTI Workqueue: kblockd blk_mq_run_work_fn RIP: 0010:kyber_has_work+0x29/0x70 ... Call Trace: __blk_mq_do_dispatch_sched+0x83/0x2b0 __blk_mq_sched_dispatch_requests+0x12e/0x170 blk_mq_sched_dispatch_requests+0x30/0x60 __blk_mq_run_hw_queue+0x2b/0x50 process_one_work+0x1ef/0x380 worker_thread+0x2d/0x3e0

Gravité et risque d'exploitation

CVE-2022-50552 obtient un score CVSS de 0.0/10, soit une gravité non évaluée. Selon le modèle EPSS, la probabilité qu'elle soit exploitée dans les 30 prochains jours est de 0.21 %, ce qui la place devant 10.4 % des CVE référencées.

Que faire ?

  • Vérifiez si Linux (versions <c478b3b2900f1834cf9eda5bfef0d5696099505d, 0, 4.19, <9646443f28f33ec545ae303e613c3f476fad4dc1, 5.15.209, <=5.10.*, d48ece209f82c9ce07be942441b53d3fa3664936, <=6.0.*, 6.1, 5.10.258, 5.19.17, <4.19, <=*, <63a681bcc32a43528ce0f690569f7f48e59c3963, <=5.15.*, <0f90015383cd3f1128bebfbe7a97122d97808046, <8237c01f1696bc53c470493bf1fe092a107648a6, 6.0.3, <=5.19.*) est présent sur votre parc.
  • Appliquez le correctif ou la version corrigée indiqués dans les références de l'éditeur.
  • À défaut de correctif, limitez l'exposition (filtrage réseau, désactivation du composant).
  • Automatisez la détection : les agents CVE Heimdall (gratuits, open source) corrèlent l'inventaire de vos serveurs avec la base CVE.

Références