CVE-2023-52864

Vulnérabilité élevée dans Linux (Linux)

CVSS 7.0 · Élevée
EPSS 0.3%
Linux•Linux•Versions : <44a96796d25809502c75771d40ee693c2e44724e, <=6.1.*, <fb7b06b59c6887659c6ed0ecd3110835eecbb6a3, 6.6.2, 0, 6.5.12, 6.1.63, 5.4.261, 5.10.201, <=5.10.*, <=6.6.*, 44b6b7661132b1b0e5fd3147ded66f1e4a817ca9, 5.15.139, <d426a2955e45a95b2282764105fcfb110a540453, <=5.4.*, <9fb0eed09e1470cd4021ff52b2b9dfcbcee4c203, <=4.19.*, <e0bf076b734a2fab92d8fddc2b8b03462eee7097, <36d85fa7ae0d6be651c1a745191fa7ef055db43e, <cf098e937dd125c0317a0d6f261ac2a950a233d6, <=*, <=5.15.*, <=6.5.*, <eba9ac7abab91c8f6d351460239108bef5e7a0b6, 6.7, <4.15, 4.19.299, 4.15

Description

In the Linux kernel, the following vulnerability has been resolved: platform/x86: wmi: Fix opening of char device Since commit fa1f68db6ca7 ("drivers: misc: pass miscdevice pointer via file private data"), the miscdevice stores a pointer to itself inside filp->private_data, which means that private_data will not be NULL when wmi_char_open() is called. This might cause memory corruption should wmi_char_open() be unable to find its driver, something which can happen when the associated WMI device is deleted in wmi_free_devices(). Fix the problem by using the miscdevice pointer to retrieve the WMI device data associated with a char device using container_of(). This also avoids wmi_char_open() picking a wrong WMI device bound to a driver with the same name as the original driver.

Gravité et risque d'exploitation

CVE-2023-52864 obtient un score CVSS de 7.0/10, soit une gravité élevée. Selon le modèle EPSS, la probabilité qu'elle soit exploitée dans les 30 prochains jours est de 0.27 %, ce qui la place devant 17.8 % des CVE référencées.

Que faire ?

  • Vérifiez si Linux (versions <44a96796d25809502c75771d40ee693c2e44724e, <=6.1.*, <fb7b06b59c6887659c6ed0ecd3110835eecbb6a3, 6.6.2, 0, 6.5.12, 6.1.63, 5.4.261, 5.10.201, <=5.10.*, <=6.6.*, 44b6b7661132b1b0e5fd3147ded66f1e4a817ca9, 5.15.139, <d426a2955e45a95b2282764105fcfb110a540453, <=5.4.*, <9fb0eed09e1470cd4021ff52b2b9dfcbcee4c203, <=4.19.*, <e0bf076b734a2fab92d8fddc2b8b03462eee7097, <36d85fa7ae0d6be651c1a745191fa7ef055db43e, <cf098e937dd125c0317a0d6f261ac2a950a233d6, <=*, <=5.15.*, <=6.5.*, <eba9ac7abab91c8f6d351460239108bef5e7a0b6, 6.7, <4.15, 4.19.299, 4.15) est présent sur votre parc.
  • Appliquez le correctif ou la version corrigée indiqués dans les références de l'éditeur.
  • À défaut de correctif, limitez l'exposition (filtrage réseau, désactivation du composant).
  • Automatisez la détection : les agents CVE Heimdall (gratuits, open source) corrèlent l'inventaire de vos serveurs avec la base CVE.

Références