CVE-2023-53530

Vulnérabilité non évaluée dans Linux (Linux)

CVSS 0.0 · Non évaluée
EPSS 0.1%
Linux•Linux•Versions : <1a541999f31fcb10ea50eba2a563e6c451fd5c7d, 35c02a333d523d9da0b482b0d751cdeb95c068ae, 6.6, <=*, <59f10a05b5c7b675256a66e3161741239889ff80, <6.3, <=6.5.*, 532a239605667320f4fd7473e416b718d0a2fbbb, 0, 6.5.5, 6.3, <52c7b41ad6ee53222f4ee2f0c099a6ed8291a168, <25bd0c7def04a272f8e89b36971712fe29c6e438, 1d201c81d4cc6840735bbcc99e6031503e5cf3b8

Description

In the Linux kernel, the following vulnerability has been resolved: scsi: qla2xxx: Use raw_smp_processor_id() instead of smp_processor_id() The following call trace was observed: localhost kernel: nvme nvme0: NVME-FC{0}: controller connect complete localhost kernel: BUG: using smp_processor_id() in preemptible [00000000] code: kworker/u129:4/75092 localhost kernel: nvme nvme0: NVME-FC{0}: new ctrl: NQN "nqn.1992-08.com.netapp:sn.b42d198afb4d11ecad6d00a098d6abfa:subsystem.PR_Channel2022_RH84_subsystem_291" localhost kernel: caller is qla_nvme_post_cmd+0x216/0x1380 [qla2xxx] localhost kernel: CPU: 6 PID: 75092 Comm: kworker/u129:4 Kdump: loaded Tainted: G B W OE --------- --- 5.14.0-70.22.1.el9_0.x86_64+debug #1 localhost kernel: Hardware name: HPE ProLiant XL420 Gen10/ProLiant XL420 Gen10, BIOS U39 01/13/2022 localhost kernel: Workqueue: nvme-wq nvme_async_event_work [nvme_core] localhost kernel: Call Trace: localhost kernel: dump_stack_lvl+0x57/0x7d localhost kernel: check_preemption_disabled+0xc8/0xd0 localhost kernel: qla_nvme_post_cmd+0x216/0x1380 [qla2xxx] Use raw_smp_processor_id() instead of smp_processor_id(). Also use queue_work() across the driver instead of queue_work_on() thus avoiding usage of smp_processor_id() when CONFIG_DEBUG_PREEMPT is enabled.

Gravité et risque d'exploitation

CVE-2023-53530 obtient un score CVSS de 0.0/10, soit une gravité non évaluée. Selon le modèle EPSS, la probabilité qu'elle soit exploitée dans les 30 prochains jours est de 0.14 %, ce qui la place devant 3.4 % des CVE référencées.

Que faire ?

  • Vérifiez si Linux (versions <1a541999f31fcb10ea50eba2a563e6c451fd5c7d, 35c02a333d523d9da0b482b0d751cdeb95c068ae, 6.6, <=*, <59f10a05b5c7b675256a66e3161741239889ff80, <6.3, <=6.5.*, 532a239605667320f4fd7473e416b718d0a2fbbb, 0, 6.5.5, 6.3, <52c7b41ad6ee53222f4ee2f0c099a6ed8291a168, <25bd0c7def04a272f8e89b36971712fe29c6e438, 1d201c81d4cc6840735bbcc99e6031503e5cf3b8) est présent sur votre parc.
  • Appliquez le correctif ou la version corrigée indiqués dans les références de l'éditeur.
  • À défaut de correctif, limitez l'exposition (filtrage réseau, désactivation du composant).
  • Automatisez la détection : les agents CVE Heimdall (gratuits, open source) corrèlent l'inventaire de vos serveurs avec la base CVE.

Références