CVE-2024-21605
Vulnérabilité élevée dans Junos OS (Juniper Networks)
Description
An Exposure of Resource to Wrong Sphere vulnerability in the Packet Forwarding Engine (PFE) of Juniper Networks Junos OS on SRX 300 Series allows an unauthenticated, adjacent attacker to cause a Denial of Service (DoS). Specific valid link-local traffic is not blocked on ports in STP blocked state but is instead sent to the control plane of the device. This leads to excessive resource consumption and in turn severe impact on all control and management protocols of the device. This issue affects Juniper Networks Junos OS: * 21.2 version 21.2R3-S3 and later versions earlier than 21.2R3-S6; * 22.1 version 22.1R3 and later versions earlier than 22.1R3-S4; * 22.2 version 22.2R2 and later versions earlier than 22.2R3-S2; * 22.3 version 22.3R2 and later versions earlier than 22.3R3-S1; * 22.4 versions earlier than 22.4R2-S2, 22.4R3; * 23.2 versions earlier than 23.2R1-S1, 23.2R2. This issue does not affect Juniper Networks Junos OS 21.4R1 and later versions of 21.4.
Gravité et risque d'exploitation
CVE-2024-21605 obtient un score CVSS de 7.1/10, soit une gravité élevée. Selon le modèle EPSS, la probabilité qu'elle soit exploitée dans les 30 prochains jours est de 0.29 %, ce qui la place devant 20.9 % des CVE référencées.
Que faire ?
- Vérifiez si Junos OS (versions <21.4*, 22.1R3, 21.4, <22.1R3-S4, 22.4, 23.2, 21.2R3-S3, 22.2R2, 22.3R2, <22.3R3-S1, <21.2R3-S6, <23.2R1-S1, 23.2R2, <22.2R3-S2, <22.4R2-S2, 22.4R3) est présent sur votre parc.
- Appliquez le correctif ou la version corrigée indiqués dans les références de l'éditeur.
- À défaut de correctif, limitez l'exposition (filtrage réseau, désactivation du composant).
- Automatisez la détection : les agents CVE Heimdall (gratuits, open source) corrèlent l'inventaire de vos serveurs avec la base CVE.