CVE-2024-26801

Vulnérabilité élevée dans Linux (Linux)

CVSS 8.8 · Élevée
EPSS 0.4%
Linux•Linux•Versions : <=6.1.*, 5.15.151, 0, 4.19.309, <45085686b9559bfbe3a4f41d3d695a520668f5e1, <2ab9a19d896f5a0dd386e1f001c5309bc35f433b, 6.8, <4.0, <6dd0a9dfa99f8990a08eb8fdd8e79bee31c7d8e2, 6.1.81, <=5.10.*, <=6.6.*, <e0b278650f07acf2e0932149183458468a731c03, 4.0, 5.4.271, <=5.4.*, <98fb98fd37e42fd4ce13ff657ea64503e24b6090, <=4.19.*, <dd594cdc24f2e48dab441732e6dfcafd6b0711d1, <=*, c7741d16a57cbf97eebe53f27e8216b1ff20e20c, 5.10.212, <=5.15.*, <2449007d3f73b2842c9734f45f0aadb522daf592, <=6.7.*, 6.6.21, 6.7.9, <da4569d450b193e39e87119fd316c0291b585d14

Description

In the Linux kernel, the following vulnerability has been resolved: Bluetooth: Avoid potential use-after-free in hci_error_reset While handling the HCI_EV_HARDWARE_ERROR event, if the underlying BT controller is not responding, the GPIO reset mechanism would free the hci_dev and lead to a use-after-free in hci_error_reset. Here's the call trace observed on a ChromeOS device with Intel AX201: queue_work_on+0x3e/0x6c __hci_cmd_sync_sk+0x2ee/0x4c0 [bluetooth <HASH:3b4a6>] ? init_wait_entry+0x31/0x31 __hci_cmd_sync+0x16/0x20 [bluetooth <HASH:3b4a 6>] hci_error_reset+0x4f/0xa4 [bluetooth <HASH:3b4a 6>] process_one_work+0x1d8/0x33f worker_thread+0x21b/0x373 kthread+0x13a/0x152 ? pr_cont_work+0x54/0x54 ? kthread_blkcg+0x31/0x31 ret_from_fork+0x1f/0x30 This patch holds the reference count on the hci_dev while processing a HCI_EV_HARDWARE_ERROR event to avoid potential crash.

Gravité et risque d'exploitation

CVE-2024-26801 obtient un score CVSS de 8.8/10, soit une gravité élevée. Selon le modèle EPSS, la probabilité qu'elle soit exploitée dans les 30 prochains jours est de 0.43 %, ce qui la place devant 35.4 % des CVE référencées.

Que faire ?

  • Vérifiez si Linux (versions <=6.1.*, 5.15.151, 0, 4.19.309, <45085686b9559bfbe3a4f41d3d695a520668f5e1, <2ab9a19d896f5a0dd386e1f001c5309bc35f433b, 6.8, <4.0, <6dd0a9dfa99f8990a08eb8fdd8e79bee31c7d8e2, 6.1.81, <=5.10.*, <=6.6.*, <e0b278650f07acf2e0932149183458468a731c03, 4.0, 5.4.271, <=5.4.*, <98fb98fd37e42fd4ce13ff657ea64503e24b6090, <=4.19.*, <dd594cdc24f2e48dab441732e6dfcafd6b0711d1, <=*, c7741d16a57cbf97eebe53f27e8216b1ff20e20c, 5.10.212, <=5.15.*, <2449007d3f73b2842c9734f45f0aadb522daf592, <=6.7.*, 6.6.21, 6.7.9, <da4569d450b193e39e87119fd316c0291b585d14) est présent sur votre parc.
  • Appliquez le correctif ou la version corrigée indiqués dans les références de l'éditeur.
  • À défaut de correctif, limitez l'exposition (filtrage réseau, désactivation du composant).
  • Automatisez la détection : les agents CVE Heimdall (gratuits, open source) corrèlent l'inventaire de vos serveurs avec la base CVE.

Références