CVE-2024-27059

Vulnérabilité non évaluée dans Linux (Linux)

CVSS 0.0 · Non évaluée
EPSS 0.2%
Linux•Linux•Versions : <=6.1.*, 2.6.12, <6c1f36d92c0a8799569055012665d2bb066fb964, <014bcf41d946b36a8f0b8e9b5d9529efbb822f49, <f42ba916689f5c7b1642092266d2f53cf527aaaa, 0, 5.15.154, 6.8, <2.6.12, 1da177e4c3f41524e886b7f1b8a0c1fc7321cac2, <=5.10.*, <=6.6.*, 5.10.215, <9968c701cba7eda42e5f0052b040349d6222ae34, <3a67d4ab9e730361d183086dfb0ddd8c61f01636, <=5.4.*, 4.19.312, <=4.19.*, 5.4.274, 6.7.12, <eb7b01ca778170654e1c76950024270ba74b121f, <=*, <871fd7b10b56d280990b7e754f43d888382ca325, <=5.15.*, <=6.7.*, <284fb1003d5da111019b9e0bf99b084fd71ac133, 6.1.84, 6.6.24

Description

In the Linux kernel, the following vulnerability has been resolved: USB: usb-storage: Prevent divide-by-0 error in isd200_ata_command The isd200 sub-driver in usb-storage uses the HEADS and SECTORS values in the ATA ID information to calculate cylinder and head values when creating a CDB for READ or WRITE commands. The calculation involves division and modulus operations, which will cause a crash if either of these values is 0. While this never happens with a genuine device, it could happen with a flawed or subversive emulation, as reported by the syzbot fuzzer. Protect against this possibility by refusing to bind to the device if either the ATA_ID_HEADS or ATA_ID_SECTORS value in the device's ID information is 0. This requires isd200_Initialization() to return a negative error code when initialization fails; currently it always returns 0 (even when there is an error).

Gravité et risque d'exploitation

CVE-2024-27059 obtient un score CVSS de 0.0/10, soit une gravité non évaluée. Selon le modèle EPSS, la probabilité qu'elle soit exploitée dans les 30 prochains jours est de 0.24 %, ce qui la place devant 14.4 % des CVE référencées.

Que faire ?

  • Vérifiez si Linux (versions <=6.1.*, 2.6.12, <6c1f36d92c0a8799569055012665d2bb066fb964, <014bcf41d946b36a8f0b8e9b5d9529efbb822f49, <f42ba916689f5c7b1642092266d2f53cf527aaaa, 0, 5.15.154, 6.8, <2.6.12, 1da177e4c3f41524e886b7f1b8a0c1fc7321cac2, <=5.10.*, <=6.6.*, 5.10.215, <9968c701cba7eda42e5f0052b040349d6222ae34, <3a67d4ab9e730361d183086dfb0ddd8c61f01636, <=5.4.*, 4.19.312, <=4.19.*, 5.4.274, 6.7.12, <eb7b01ca778170654e1c76950024270ba74b121f, <=*, <871fd7b10b56d280990b7e754f43d888382ca325, <=5.15.*, <=6.7.*, <284fb1003d5da111019b9e0bf99b084fd71ac133, 6.1.84, 6.6.24) est présent sur votre parc.
  • Appliquez le correctif ou la version corrigée indiqués dans les références de l'éditeur.
  • À défaut de correctif, limitez l'exposition (filtrage réseau, désactivation du composant).
  • Automatisez la détection : les agents CVE Heimdall (gratuits, open source) corrèlent l'inventaire de vos serveurs avec la base CVE.

Références