CVE-2024-39469

Vulnérabilité élevée dans Linux (Linux)

CVSS 7.1 · Élevée
EPSS 0.3%
Linux•Linux•Versions : <2ac8a2fe22bdde9eecce2a42cf5cab79333fb428, <=6.1.*, 5.4.279, 2ba466d74ed74f073257f86e61519cb8f8f46184, 6.10, 6.1.95, <7373a51e7998b508af7136530f3a997b286ce81c, 0, 6.6.35, 6.9.5, <=5.10.*, 2.6.30, <=6.6.*, <=6.9.*, <d18b05eda7fa77f02114f15b02c009f28ee42346, 5.15.162, <=5.4.*, <c77ad608df6c091fe64ecb91f41ef7cb465587f1, <11a2edb70356a2202dcb7c9c189c8356ab4752cd, <59f14875a96ef93f05b82ad3c980605f2cb444b5, <2.6.30, <=4.19.*, 5.10.221, <129dcd3e7d036218db3f59c82d82004b9539ed82, <405b71f1251e5ae865f53bd27c45114e6c83bee3, <=*, <=5.15.*, 4.19.317

Description

In the Linux kernel, the following vulnerability has been resolved: nilfs2: fix nilfs_empty_dir() misjudgment and long loop on I/O errors The error handling in nilfs_empty_dir() when a directory folio/page read fails is incorrect, as in the old ext2 implementation, and if the folio/page cannot be read or nilfs_check_folio() fails, it will falsely determine the directory as empty and corrupt the file system. In addition, since nilfs_empty_dir() does not immediately return on a failed folio/page read, but continues to loop, this can cause a long loop with I/O if i_size of the directory's inode is also corrupted, causing the log writer thread to wait and hang, as reported by syzbot. Fix these issues by making nilfs_empty_dir() immediately return a false value (0) if it fails to get a directory folio/page.

Gravité et risque d'exploitation

CVE-2024-39469 obtient un score CVSS de 7.1/10, soit une gravité élevée. Selon le modèle EPSS, la probabilité qu'elle soit exploitée dans les 30 prochains jours est de 0.25 %, ce qui la place devant 15.6 % des CVE référencées.

Que faire ?

  • Vérifiez si Linux (versions <2ac8a2fe22bdde9eecce2a42cf5cab79333fb428, <=6.1.*, 5.4.279, 2ba466d74ed74f073257f86e61519cb8f8f46184, 6.10, 6.1.95, <7373a51e7998b508af7136530f3a997b286ce81c, 0, 6.6.35, 6.9.5, <=5.10.*, 2.6.30, <=6.6.*, <=6.9.*, <d18b05eda7fa77f02114f15b02c009f28ee42346, 5.15.162, <=5.4.*, <c77ad608df6c091fe64ecb91f41ef7cb465587f1, <11a2edb70356a2202dcb7c9c189c8356ab4752cd, <59f14875a96ef93f05b82ad3c980605f2cb444b5, <2.6.30, <=4.19.*, 5.10.221, <129dcd3e7d036218db3f59c82d82004b9539ed82, <405b71f1251e5ae865f53bd27c45114e6c83bee3, <=*, <=5.15.*, 4.19.317) est présent sur votre parc.
  • Appliquez le correctif ou la version corrigée indiqués dans les références de l'éditeur.
  • À défaut de correctif, limitez l'exposition (filtrage réseau, désactivation du composant).
  • Automatisez la détection : les agents CVE Heimdall (gratuits, open source) corrèlent l'inventaire de vos serveurs avec la base CVE.

Références