CVE-2024-39547

Vulnérabilité élevée dans Junos OS (Juniper Networks)

CVSS 8.7 · Élevée
EPSS 1.0%
Juniper Networks•Junos OS•Versions : <21.4R3-S7, <22.2R3-S4, <22.3R3-S3, 23.2, <23.2R2-EVO, 0, <22.4R3-S2-EVO, 22.4-EVO, 21.4, 22.2, <21.2R3-S8, 22.1, <22.2R3-S4-EVO, <22.4R3-S2, <22.1R3-S6, <24.2R2, <21.4R3-S7-EVO, 22.2-EVO, 22.4, <23.2R2-S2, 22.3-EVO, 23.2-EVO, <22.3R3-S3-EVO, 24.2, 22.3

Description

An Improper Handling of Exceptional Conditions vulnerability in the rpd-server of Juniper Networks Junos OS and Junos OS Evolved within cRPD allows an unauthenticated network-based attacker sending crafted TCP traffic to the routing engine (RE) to cause a CPU-based Denial of Service (DoS). If specially crafted TCP traffic is received by the control plane, or a TCP session terminates unexpectedly, it will cause increased control plane CPU utilization by the rpd-server process. While not explicitly required, the impact is more severe when RIB sharding is enabled. Task accounting shows unexpected reads by the RPD Server jobs for shards: user@junos> show task accounting detail ... read:RPD Server.0.0.0.0+780.192.168.0.78+48886 TOT:00000003.00379787 MAX:00000000.00080516 RUNS: 233888\ read:RPD Server.0.0.0.0+780.192.168.0.78+49144 TOT:00000004.00007565 MAX:00000000.00080360 RUNS: 233888\ read:RPD Server.0.0.0.0+780.192.168.0.78+49694 TOT:00000003.00600584 MAX:00000000.00080463 RUNS: 233888\ read:RPD Server.0.0.0.0+780.192.168.0.78+50246 TOT:00000004.00346998 MAX:00000000.00080338 RUNS: 233888\ This issue affects: Junos OS with cRPD:  * All versions before 21.2R3-S8,  * 21.4 before 21.4R3-S7,  * 22.1 before 22.1R3-S6,  * 22.2 before 22.2R3-S4,  * 22.3 before 22.3R3-S3,  * 22.4 before 22.4R3-S2,  * 23.2 before 23.2R2-S2,  * 24.2 before 24.2R2;  Junos OS Evolved with cRPD:  * All versions before 21.4R3-S7-EVO,  * 22.2 before 22.2R3-S4-EVO,  * 22.3 before 22.3R3-S3-EVO,  * 22.4 before 22.4R3-S2-EVO,  * 23.2 before 23.2R2-EVO.

Gravité et risque d'exploitation

CVE-2024-39547 obtient un score CVSS de 8.7/10, soit une gravité élevée. Selon le modèle EPSS, la probabilité qu'elle soit exploitée dans les 30 prochains jours est de 0.97 %, ce qui la place devant 61.1 % des CVE référencées.

Que faire ?

  • Vérifiez si Junos OS (versions <21.4R3-S7, <22.2R3-S4, <22.3R3-S3, 23.2, <23.2R2-EVO, 0, <22.4R3-S2-EVO, 22.4-EVO, 21.4, 22.2, <21.2R3-S8, 22.1, <22.2R3-S4-EVO, <22.4R3-S2, <22.1R3-S6, <24.2R2, <21.4R3-S7-EVO, 22.2-EVO, 22.4, <23.2R2-S2, 22.3-EVO, 23.2-EVO, <22.3R3-S3-EVO, 24.2, 22.3) est présent sur votre parc.
  • Appliquez le correctif ou la version corrigée indiqués dans les références de l'éditeur.
  • À défaut de correctif, limitez l'exposition (filtrage réseau, désactivation du composant).
  • Automatisez la détection : les agents CVE Heimdall (gratuits, open source) corrèlent l'inventaire de vos serveurs avec la base CVE.

Références