CVE-2024-42018
Vulnérabilité élevée
Description
An issue was discovered in Atos Eviden SMC xScale before 1.6.6. During initialization of nodes, some configuration parameters are retrieved from management nodes. These parameters embed credentials whose integrity and confidentiality may be important to the security of the HPC configuration. Because these parameters are needed for initialization, there is no available mechanism to ensure access control on the management node, and a mitigation measure is normally put in place to prevent access to unprivileged users. It was discovered that this mitigation measure does not survive a reboot of diskful nodes. (Diskless nodes are not at risk.) The mistake lies in the cloudinit configuration: the iptables configuration should have been in the bootcmd instead of the runcmd section.
Gravité et risque d'exploitation
CVE-2024-42018 obtient un score CVSS de 7.7/10, soit une gravité élevée. Selon le modèle EPSS, la probabilité qu'elle soit exploitée dans les 30 prochains jours est de 0.36 %, ce qui la place devant 28.0 % des CVE référencées.
Que faire ?
- Vérifiez si le produit concerné est présent sur votre parc.
- Appliquez le correctif ou la version corrigée indiqués dans les références de l'éditeur.
- À défaut de correctif, limitez l'exposition (filtrage réseau, désactivation du composant).
- Automatisez la détection : les agents CVE Heimdall (gratuits, open source) corrèlent l'inventaire de vos serveurs avec la base CVE.