CVE-2024-43649

Vulnérabilité critique dans Iocharger firmware for AC models (Iocharger)

CVSS 9.3 · Critique
EPSS 1.8%
Iocharger•Iocharger firmware for AC models•Versions : <24120701, 0

Description

Authenticated command injection in the filename of a <redacted>.exe request leads to remote code execution as the root user. This issue affects Iocharger firmware for AC models before version 24120701. Likelihood: Moderate – This action is not a common place for command injection vulnerabilities to occur. Thus, an attacker will likely only be able to find this vulnerability by reverse-engineering the firmware or trying it on all <redacted> fields. The attacker will also need a (low privilege) account to gain access to the <redacted> binary, or convince a user with such access to execute a payload. Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and delete files and services. CVSS clarification: This attack can be performed over any network conenction serving the web interfacr (AV:N), and there are not additional mitigating measures that need to be circumvented (AC:L) or other prerequisites (AT:N). The attack does require privileges, but the level does not matter (PR:L), there is no user interaction required (UI:N). The attack leeds to a full compromised of the charger (VC:H/VI:H/VA:H) and a compromised charger can be used to "pivot" to networks that should normally not be reachable (SC:L/SI:L/SA:H). Because this is an EV chargers with significant pwoer, there is a potential safety imp0act (S:P). THis attack can be automated (AU:Y).

Gravité et risque d'exploitation

CVE-2024-43649 obtient un score CVSS de 9.3/10, soit une gravité critique. Selon le modèle EPSS, la probabilité qu'elle soit exploitée dans les 30 prochains jours est de 1.83 %, ce qui la place devant 78.5 % des CVE référencées.

Que faire ?

  • Vérifiez si Iocharger firmware for AC models (versions <24120701, 0) est présent sur votre parc.
  • Appliquez le correctif ou la version corrigée indiqués dans les références de l'éditeur.
  • À défaut de correctif, limitez l'exposition (filtrage réseau, désactivation du composant).
  • Automatisez la détection : les agents CVE Heimdall (gratuits, open source) corrèlent l'inventaire de vos serveurs avec la base CVE.

Références