CVE-2024-49849

Vulnérabilité élevée dans SIMATIC S7-PLCSIM V16 (Siemens)

CVSS 8.4 · Élevée
EPSS 0.2%
Siemens•SIMATIC S7-PLCSIM V16•Versions : <V17 Update 9, <V18 Update 6, <V19 Update 4, 0, <V5.6 SP1 HF7, <V5.2.1.1, <*, <V6.3.0.2

Description

A vulnerability has been identified in SIMATIC S7-PLCSIM V16 (All versions), SIMATIC S7-PLCSIM V17 (All versions), SIMATIC STEP 7 Safety V16 (All versions), SIMATIC STEP 7 Safety V17 (All versions < V17 Update 9), SIMATIC STEP 7 Safety V18 (All versions < V18 Update 6), SIMATIC STEP 7 Safety V19 (All versions < V19 Update 4), SIMATIC STEP 7 V16 (All versions), SIMATIC STEP 7 V17 (All versions < V17 Update 9), SIMATIC STEP 7 V18 (All versions < V18 Update 6), SIMATIC STEP 7 V19 (All versions < V19 Update 4), SIMATIC WinCC Unified V16 (All versions), SIMATIC WinCC Unified V17 (All versions < V17 Update 9), SIMATIC WinCC Unified V18 (All versions < V18 Update 6), SIMATIC WinCC Unified V19 (All versions < V19 Update 4), SIMATIC WinCC V16 (All versions), SIMATIC WinCC V17 (All versions < V17 Update 9), SIMATIC WinCC V18 (All versions < V18 Update 6), SIMATIC WinCC V19 (All versions < V19 Update 4), SIMOCODE ES V16 (All versions), SIMOCODE ES V17 (All versions), SIMOCODE ES V18 (All versions), SIMOCODE ES V19 (All versions), SIMOTION SCOUT TIA V5.4 (All versions), SIMOTION SCOUT TIA V5.5 (All versions), SIMOTION SCOUT TIA V5.6 (All versions < V5.6 SP1 HF7), SINAMICS Startdrive V16 (All versions), SINAMICS Startdrive V17 (All versions), SINAMICS Startdrive V18 (All versions), SINAMICS Startdrive V19 (All versions), SIRIUS Safety ES V17 (TIA Portal) (All versions), SIRIUS Safety ES V18 (TIA Portal) (All versions < V18 Update 6), SIRIUS Safety ES V19 (TIA Portal) (All versions), SIRIUS Soft Starter ES V17 (TIA Portal) (All versions), SIRIUS Soft Starter ES V18 (TIA Portal) (All versions), SIRIUS Soft Starter ES V19 (TIA Portal) (All versions), TIA Portal Cloud V16 (All versions), TIA Portal Cloud V17 (All versions), TIA Portal Cloud V18 (All versions < V6.3.0.2), TIA Portal Cloud V19 (All versions < V5.2.1.1). Affected products do not properly sanitize user-controllable input when parsing log files. This could allow an attacker to cause a type confusion and execute arbitrary code within the affected application.

Gravité et risque d'exploitation

CVE-2024-49849 obtient un score CVSS de 8.4/10, soit une gravité élevée. Selon le modèle EPSS, la probabilité qu'elle soit exploitée dans les 30 prochains jours est de 0.22 %, ce qui la place devant 11.2 % des CVE référencées.

Que faire ?

  • Vérifiez si SIMATIC S7-PLCSIM V16 (versions <V17 Update 9, <V18 Update 6, <V19 Update 4, 0, <V5.6 SP1 HF7, <V5.2.1.1, <*, <V6.3.0.2) est présent sur votre parc.
  • Appliquez le correctif ou la version corrigée indiqués dans les références de l'éditeur.
  • À défaut de correctif, limitez l'exposition (filtrage réseau, désactivation du composant).
  • Automatisez la détection : les agents CVE Heimdall (gratuits, open source) corrèlent l'inventaire de vos serveurs avec la base CVE.

Références