CVE-2024-51981

Vulnérabilité moyenne dans HL-L8260CDN (Brother Industries, Ltd)

CVSS 5.3 · Moyenne
EPSS 1.0%
Brother Industries, Ltd•HL-L8260CDN•Versions : <=1.15, <=1.30, 0, <=T, <=1.12(E), <=G, <=M2403271743, <=1.27(W), <=1.18, <=1.18(L), <=1.32, <=V, <=2.11, <=ZD, <=1.23(N), <=M2309191611, <=H, <=1.11(G), <=1.16(G), <=1.11(J), <=1.29(J), <=M2309191505, <=1.36(ZA), <=1.06(C), <=1.03(A), A, <=1.10(F), <=1.12(F), <=1.95(ZH), <=1.14(H), <=1.12(J), <=N2403271808, <=M, <=1.03(B), <=1.16(F), <=1.27, <=U, <=1.15(L), <=1.09(F), <=1.21(M), <=1.08(C), <=1.39(ZA), <=2.19, <=ZM, <=1.16(L), <=F, <=1.05(B), <=1.14(M), <=X, <=1.14(J), <=1.07(G), <=1.15(J), <=1.25(L), <=1.74(ZE), <=1.13(L), <=1.01(A), <=1.15(K), <=1.10(G), <=P, <=1.24, <=1.40(R), <=W, <=S, <=ZA, <=1.28, <=L, <=1.38, <=1.04(C), <=1.10, <=1.02(B), <=ZZ, <=1.06(E), <=1.15(H), <=E, <=1.21, <=ZK, <=1.03D(D), <=Q, <=1.68(ZG), <=1.19(H), <=Z, <=N, <=1.19, <=R, <=1.33, <=1.04(D), <=1.20(J), <=1.16(J), <=1.23(Q), <=1.25(J), <=1.20(L), <=1.13(H), <=Y, <=1.22(T), <=K, <=1.12, <=1.12(H), <=1.25(W), <=1.36(Z), <=1.06(F), <=1.44, <=1.08, <=1.19(M), <=J, <=ZE, <=1.13(E), <=1.16(H), <=1.82(ZG), <=1.02(A), <=U2406280431 (Ver R), <=1.22(S), 1.0, <=ZP, <=1.22, <=1.65(ZH), <=1.09(C), <=1.27(K), <=1.03(C), <=ZC, <=1.11(K), <=1.38(L), <=1.38(M), <=1.18(J), <=ZB

Description

An unauthenticated attacker may perform a blind server side request forgery (SSRF), due to a CLRF injection issue that can be leveraged to perform HTTP request smuggling. This SSRF leverages the WS-Addressing feature used during a WS-Eventing subscription SOAP operation. The attacker can control all the HTTP data sent in the SSRF connection, but the attacker can not receive any data back from this connection.

Gravité et risque d'exploitation

CVE-2024-51981 obtient un score CVSS de 5.3/10, soit une gravité moyenne. Selon le modèle EPSS, la probabilité qu'elle soit exploitée dans les 30 prochains jours est de 0.98 %, ce qui la place devant 61.6 % des CVE référencées.

Que faire ?

  • Vérifiez si HL-L8260CDN (versions <=1.15, <=1.30, 0, <=T, <=1.12(E), <=G, <=M2403271743, <=1.27(W), <=1.18, <=1.18(L), <=1.32, <=V, <=2.11, <=ZD, <=1.23(N), <=M2309191611, <=H, <=1.11(G), <=1.16(G), <=1.11(J), <=1.29(J), <=M2309191505, <=1.36(ZA), <=1.06(C), <=1.03(A), A, <=1.10(F), <=1.12(F), <=1.95(ZH), <=1.14(H), <=1.12(J), <=N2403271808, <=M, <=1.03(B), <=1.16(F), <=1.27, <=U, <=1.15(L), <=1.09(F), <=1.21(M), <=1.08(C), <=1.39(ZA), <=2.19, <=ZM, <=1.16(L), <=F, <=1.05(B), <=1.14(M), <=X, <=1.14(J), <=1.07(G), <=1.15(J), <=1.25(L), <=1.74(ZE), <=1.13(L), <=1.01(A), <=1.15(K), <=1.10(G), <=P, <=1.24, <=1.40(R), <=W, <=S, <=ZA, <=1.28, <=L, <=1.38, <=1.04(C), <=1.10, <=1.02(B), <=ZZ, <=1.06(E), <=1.15(H), <=E, <=1.21, <=ZK, <=1.03D(D), <=Q, <=1.68(ZG), <=1.19(H), <=Z, <=N, <=1.19, <=R, <=1.33, <=1.04(D), <=1.20(J), <=1.16(J), <=1.23(Q), <=1.25(J), <=1.20(L), <=1.13(H), <=Y, <=1.22(T), <=K, <=1.12, <=1.12(H), <=1.25(W), <=1.36(Z), <=1.06(F), <=1.44, <=1.08, <=1.19(M), <=J, <=ZE, <=1.13(E), <=1.16(H), <=1.82(ZG), <=1.02(A), <=U2406280431 (Ver R), <=1.22(S), 1.0, <=ZP, <=1.22, <=1.65(ZH), <=1.09(C), <=1.27(K), <=1.03(C), <=ZC, <=1.11(K), <=1.38(L), <=1.38(M), <=1.18(J), <=ZB) est présent sur votre parc.
  • Appliquez le correctif ou la version corrigée indiqués dans les références de l'éditeur.
  • À défaut de correctif, limitez l'exposition (filtrage réseau, désactivation du composant).
  • Automatisez la détection : les agents CVE Heimdall (gratuits, open source) corrèlent l'inventaire de vos serveurs avec la base CVE.

Références