CVE-2024-57899

Vulnérabilité élevée dans Linux (Linux)

CVSS 7.6 · Élevée
EPSS 0.3%
Linux•Linux•Versions : 6.13, <=*, <=6.12.*, <49dba1ded8dd5a6a12748631403240b2ab245c34, 6.5, <6.5, <36b739637d7042843f9df57212ecee6ed6e0d4b2, <=6.6.*, 6.6.70, 0, 6.12.9, 15ddba5f43114c1fd9cd83676e04a9e1acf8e37f, <86772872f9f5097cd03d0e1c6813238bd38c250b

Description

In the Linux kernel, the following vulnerability has been resolved: wifi: mac80211: fix mbss changed flags corruption on 32 bit systems On 32-bit systems, the size of an unsigned long is 4 bytes, while a u64 is 8 bytes. Therefore, when using or_each_set_bit(bit, &bits, sizeof(changed) * BITS_PER_BYTE), the code is incorrectly searching for a bit in a 32-bit variable that is expected to be 64 bits in size, leading to incorrect bit finding. Solution: Ensure that the size of the bits variable is correctly adjusted for each architecture. Call Trace: ? show_regs+0x54/0x58 ? __warn+0x6b/0xd4 ? ieee80211_link_info_change_notify+0xcc/0xd4 [mac80211] ? report_bug+0x113/0x150 ? exc_overflow+0x30/0x30 ? handle_bug+0x27/0x44 ? exc_invalid_op+0x18/0x50 ? handle_exception+0xf6/0xf6 ? exc_overflow+0x30/0x30 ? ieee80211_link_info_change_notify+0xcc/0xd4 [mac80211] ? exc_overflow+0x30/0x30 ? ieee80211_link_info_change_notify+0xcc/0xd4 [mac80211] ? ieee80211_mesh_work+0xff/0x260 [mac80211] ? cfg80211_wiphy_work+0x72/0x98 [cfg80211] ? process_one_work+0xf1/0x1fc ? worker_thread+0x2c0/0x3b4 ? kthread+0xc7/0xf0 ? mod_delayed_work_on+0x4c/0x4c ? kthread_complete_and_exit+0x14/0x14 ? ret_from_fork+0x24/0x38 ? kthread_complete_and_exit+0x14/0x14 ? ret_from_fork_asm+0xf/0x14 ? entry_INT80_32+0xf0/0xf0 [restore no-op path for no changes]

Gravité et risque d'exploitation

CVE-2024-57899 obtient un score CVSS de 7.6/10, soit une gravité élevée. Selon le modèle EPSS, la probabilité qu'elle soit exploitée dans les 30 prochains jours est de 0.32 %, ce qui la place devant 23.3 % des CVE référencées.

Que faire ?

  • Vérifiez si Linux (versions 6.13, <=*, <=6.12.*, <49dba1ded8dd5a6a12748631403240b2ab245c34, 6.5, <6.5, <36b739637d7042843f9df57212ecee6ed6e0d4b2, <=6.6.*, 6.6.70, 0, 6.12.9, 15ddba5f43114c1fd9cd83676e04a9e1acf8e37f, <86772872f9f5097cd03d0e1c6813238bd38c250b) est présent sur votre parc.
  • Appliquez le correctif ou la version corrigée indiqués dans les références de l'éditeur.
  • À défaut de correctif, limitez l'exposition (filtrage réseau, désactivation du composant).
  • Automatisez la détection : les agents CVE Heimdall (gratuits, open source) corrèlent l'inventaire de vos serveurs avec la base CVE.

Références