CVE-2025-14857

Vulnérabilité moyenne dans LR1110 (Semtech)

CVSS 5.4 · Moyenne
EPSS 0.2%
Semtech•LR1110•Versions : <TRX FW 0x0202, <TRX FW 0x0104, <TRX FW 0x0402, 0

Description

An improper access control vulnerability exists in Semtech LoRa LR11xxx transceivers running early versions of firmware where the memory write command accessible via the physical SPI interface fails to enforce write protection on the program call stack. An attacker with physical access to the SPI interface can overwrite stack memory to hijack program control flow and achieve limited arbitrary code execution. However, the impact is limited to the active attack session: the device's secure boot mechanism prevents persistent firmware modification, the crypto engine isolates cryptographic keys from direct firmware access, and all modifications are lost upon device reboot or loss of physical access.

Gravité et risque d'exploitation

CVE-2025-14857 obtient un score CVSS de 5.4/10, soit une gravité moyenne. Selon le modèle EPSS, la probabilité qu'elle soit exploitée dans les 30 prochains jours est de 0.24 %, ce qui la place devant 14.6 % des CVE référencées.

Que faire ?

  • Vérifiez si LR1110 (versions <TRX FW 0x0202, <TRX FW 0x0104, <TRX FW 0x0402, 0) est présent sur votre parc.
  • Appliquez le correctif ou la version corrigée indiqués dans les références de l'éditeur.
  • À défaut de correctif, limitez l'exposition (filtrage réseau, désactivation du composant).
  • Automatisez la détection : les agents CVE Heimdall (gratuits, open source) corrèlent l'inventaire de vos serveurs avec la base CVE.

Références