CVE-2025-20316
Vulnérabilité moyenne dans Cisco IOS XE Software (Cisco)
Description
A vulnerability in the access control list (ACL) programming of Cisco IOS XE Software for Cisco Catalyst 9500X and 9600X Series Switches could allow an unauthenticated, remote attacker to bypass a configured ACL on an affected device. This vulnerability is due to the flooding of traffic from an unlearned MAC address on a switch virtual interface (SVI) that has an egress ACL applied. An attacker could exploit this vulnerability by causing the VLAN to flush its MAC address table. This condition can also occur if the MAC address table is full. A successful exploit could allow the attacker to bypass an egress ACL on an affected device.
Gravité et risque d'exploitation
CVE-2025-20316 obtient un score CVSS de 5.3/10, soit une gravité moyenne. Selon le modèle EPSS, la probabilité qu'elle soit exploitée dans les 30 prochains jours est de 0.34 %, ce qui la place devant 25.4 % des CVE référencées.
Que faire ?
- Vérifiez si Cisco IOS XE Software (versions 17.9.4, 17.15.2b, 17.9.3, 17.10.1, 17.14.1, 17.12.2, 17.9.4a, 17.10.1b, 17.12.3, 17.12.5, 17.9.7, 17.12.4, 17.15.2, 17.9.5, 17.16.1, 17.9.2, 17.9.6, 17.12.1, 17.15.1, 17.15.3, 17.9.1, 17.8.1, 17.17.1, 17.13.1, 17.7.1, 17.9.6a, 17.11.1) est présent sur votre parc.
- Appliquez le correctif ou la version corrigée indiqués dans les références de l'éditeur.
- À défaut de correctif, limitez l'exposition (filtrage réseau, désactivation du composant).
- Automatisez la détection : les agents CVE Heimdall (gratuits, open source) corrèlent l'inventaire de vos serveurs avec la base CVE.