CVE-2025-30240

Vulnérabilité moyenne dans HB810(US2) V1.0/1.6/2.0/2.6 (TP-Link Systems Inc.)

CVSS 5.1 · Moyenne
EPSS 0.2%
TP-Link Systems Inc.•HB810(US2) V1.0/1.6/2.0/2.6•Versions : 0, <0.4.0 3.1.9 v6087.0 Build 250928 Rel.59674n, <0.8.0 3.0.0 v60d5.0 Build 260318 Rel.78363n, <0.6.0 3.0.0 v60af.0 Build 251216 Rel.46954n, <800.0.16, <0.3.0 3.1.10 v6107.0 Build 250425 Rel.71973n, <0.20.0 2.0.0 v609b.0 Build 260427 Rel.16915, <0.4.0 3.1.10 v60dc.0 Build 250520 Rel.69748n, <0.6.0 3.0.0 v608b.0 Build 250613 Rel.10497n, <0.19.0 2.0.0 v609b.0 Build 250814 Rel.49732n, <0.5.0 3.0.0 v60d5.0 Build 250922 Rel.13742n, <0.8.0 3.2.2 v6080.0 Build 260309 Rel.54790n, <0.10.0 3.2.2 v6095.0 Build 260306 Rel.47567n, <0.6.0 3.0.0 v6096.0 Build 250416 Rel.26048n, <0.3.0 3.0.0 v60be.0 Build 251128 Rel.43956n, <0.3.0 3.0.0 v60bf.0 Build 250901 Rel.45574n, <0.14.0 2.0.0 v6092.0 Build 250417 Rel.24761n, <0.1.0 3.0.0 v60ee.0 Build 250310 Rel.55637n, <0.2.0 2.0.0 v60df.0 Build 250427 Rel.38233n, <0.6.0 3.0.0 v60af.0 Build 251204 Rel.20362n, <0.2.0 3.0.0 v60f9.0 Build 250826 Rel.47715n, <0.9.0 3.2.2 v6095.0 Build 260717 Rel.67188n, <1.16.0 0.8.0 v6062.0 Build 250817 Rel.23310n, <0.20.0 2.0.0 v605f.0 Build 250305 Rel.14728n

Description

The affected TP-Link Aginet devices do not properly validate symbolic links created on external USB storage devices. By placing a crafted symbolic link on supported storage media, an attacker may cause the system to resolve the link. Successful exploitation may allow unauthorized read access to sensitive files within the device filesystem.

Gravité et risque d'exploitation

CVE-2025-30240 obtient un score CVSS de 5.1/10, soit une gravité moyenne. Selon le modèle EPSS, la probabilité qu'elle soit exploitée dans les 30 prochains jours est de 0.23 %, ce qui la place devant 13.1 % des CVE référencées.

Que faire ?

  • Vérifiez si HB810(US2) V1.0/1.6/2.0/2.6 (versions 0, <0.4.0 3.1.9 v6087.0 Build 250928 Rel.59674n, <0.8.0 3.0.0 v60d5.0 Build 260318 Rel.78363n, <0.6.0 3.0.0 v60af.0 Build 251216 Rel.46954n, <800.0.16, <0.3.0 3.1.10 v6107.0 Build 250425 Rel.71973n, <0.20.0 2.0.0 v609b.0 Build 260427 Rel.16915, <0.4.0 3.1.10 v60dc.0 Build 250520 Rel.69748n, <0.6.0 3.0.0 v608b.0 Build 250613 Rel.10497n, <0.19.0 2.0.0 v609b.0 Build 250814 Rel.49732n, <0.5.0 3.0.0 v60d5.0 Build 250922 Rel.13742n, <0.8.0 3.2.2 v6080.0 Build 260309 Rel.54790n, <0.10.0 3.2.2 v6095.0 Build 260306 Rel.47567n, <0.6.0 3.0.0 v6096.0 Build 250416 Rel.26048n, <0.3.0 3.0.0 v60be.0 Build 251128 Rel.43956n, <0.3.0 3.0.0 v60bf.0 Build 250901 Rel.45574n, <0.14.0 2.0.0 v6092.0 Build 250417 Rel.24761n, <0.1.0 3.0.0 v60ee.0 Build 250310 Rel.55637n, <0.2.0 2.0.0 v60df.0 Build 250427 Rel.38233n, <0.6.0 3.0.0 v60af.0 Build 251204 Rel.20362n, <0.2.0 3.0.0 v60f9.0 Build 250826 Rel.47715n, <0.9.0 3.2.2 v6095.0 Build 260717 Rel.67188n, <1.16.0 0.8.0 v6062.0 Build 250817 Rel.23310n, <0.20.0 2.0.0 v605f.0 Build 250305 Rel.14728n) est présent sur votre parc.
  • Appliquez le correctif ou la version corrigée indiqués dans les références de l'éditeur.
  • À défaut de correctif, limitez l'exposition (filtrage réseau, désactivation du composant).
  • Automatisez la détection : les agents CVE Heimdall (gratuits, open source) corrèlent l'inventaire de vos serveurs avec la base CVE.

Références