CVE-2025-38512

Vulnérabilité élevée dans Linux (Linux)

CVSS 8.8 · Élevée
EPSS 0.2%
Linux•Linux•Versions : <=6.1.*, <737bb912ebbe4571195c56eba557c4d7315b26fb, <=6.12.*, 0, 6.1.146, 6.15.7, 6.12.39, <=6.15.*, <6.3, <=6.6.*, 986e43b19ae9176093da35e0a844e65c8bf9ede7, 6.3, 6.16, 6.1.107, 6.6.99, <e2c8a3c0388aef6bfc4aabfba07bc7dff16eea80, <ec6392061de6681148b63ee6c8744da833498cdd, <=*, <6.1.146, <6e3b09402cc6c3e3474fa548e8adf6897dda05de, <e01851f6e9a665a6011b14714b271d3e6b0b8d32, 79720743421753ff72bfa0d79976c534645b81c1

Description

In the Linux kernel, the following vulnerability has been resolved: wifi: prevent A-MSDU attacks in mesh networks This patch is a mitigation to prevent the A-MSDU spoofing vulnerability for mesh networks. The initial update to the IEEE 802.11 standard, in response to the FragAttacks, missed this case (CVE-2025-27558). It can be considered a variant of CVE-2020-24588 but for mesh networks. This patch tries to detect if a standard MSDU was turned into an A-MSDU by an adversary. This is done by parsing a received A-MSDU as a standard MSDU, calculating the length of the Mesh Control header, and seeing if the 6 bytes after this header equal the start of an rfc1042 header. If equal, this is a strong indication of an ongoing attack attempt. This defense was tested with mac80211_hwsim against a mesh network that uses an empty Mesh Address Extension field, i.e., when four addresses are used, and when using a 12-byte Mesh Address Extension field, i.e., when six addresses are used. Functionality of normal MSDUs and A-MSDUs was also tested, and confirmed working, when using both an empty and 12-byte Mesh Address Extension field. It was also tested with mac80211_hwsim that A-MSDU attacks in non-mesh networks keep being detected and prevented. Note that the vulnerability being patched, and the defense being implemented, was also discussed in the following paper and in the following IEEE 802.11 presentation: https://papers.mathyvanhoef.com/wisec2025.pdf https://mentor.ieee.org/802.11/dcn/25/11-25-0949-00-000m-a-msdu-mesh-spoof-protection.docx

Gravité et risque d'exploitation

CVE-2025-38512 obtient un score CVSS de 8.8/10, soit une gravité élevée. Selon le modèle EPSS, la probabilité qu'elle soit exploitée dans les 30 prochains jours est de 0.24 %, ce qui la place devant 13.7 % des CVE référencées.

Que faire ?

  • Vérifiez si Linux (versions <=6.1.*, <737bb912ebbe4571195c56eba557c4d7315b26fb, <=6.12.*, 0, 6.1.146, 6.15.7, 6.12.39, <=6.15.*, <6.3, <=6.6.*, 986e43b19ae9176093da35e0a844e65c8bf9ede7, 6.3, 6.16, 6.1.107, 6.6.99, <e2c8a3c0388aef6bfc4aabfba07bc7dff16eea80, <ec6392061de6681148b63ee6c8744da833498cdd, <=*, <6.1.146, <6e3b09402cc6c3e3474fa548e8adf6897dda05de, <e01851f6e9a665a6011b14714b271d3e6b0b8d32, 79720743421753ff72bfa0d79976c534645b81c1) est présent sur votre parc.
  • Appliquez le correctif ou la version corrigée indiqués dans les références de l'éditeur.
  • À défaut de correctif, limitez l'exposition (filtrage réseau, désactivation du composant).
  • Automatisez la détection : les agents CVE Heimdall (gratuits, open source) corrèlent l'inventaire de vos serveurs avec la base CVE.

Références