CVE-2025-39766

Vulnérabilité non évaluée dans Linux (Linux)

CVSS 0.0 · Non évaluée
EPSS 0.2%
Linux•Linux•Versions : <=6.1.*, <de04ddd2980b48caa8d7e24a7db2742917a8b280, <=6.12.*, 6.12.44, <710866fc0a64eafcb8bacd91bcb1329eb7e5035f, <=6.16.*, 6.17, 0, <0dacfc5372e314d1219f03e64dde3ab495a5a25e, <7689ab22de36f8db19095f6bdf11f28cfde92f5c, 5.4.297, 6.6.103, 4.19, <=5.10.*, <=6.6.*, 5.15.190, <62d591dde4defb1333d202410609c4ddeae060b3, <=5.4.*, <aa12ee1c1bd260943fd6ab556d8635811c332eeb, <15de71d06a400f7fdc15bf377a2552b0ec437cf5, 6.1.149, <4.19, 5.10.241, <=*, 046f6fd5daefac7f5abdafb436b30f63bc7c602b, <=5.15.*, <ff57186b2cc39766672c4c0332323933e5faaa88, 6.16.4

Description

In the Linux kernel, the following vulnerability has been resolved: net/sched: Make cake_enqueue return NET_XMIT_CN when past buffer_limit The following setup can trigger a WARNING in htb_activate due to the condition: !cl->leaf.q->q.qlen tc qdisc del dev lo root tc qdisc add dev lo root handle 1: htb default 1 tc class add dev lo parent 1: classid 1:1 \ htb rate 64bit tc qdisc add dev lo parent 1:1 handle f: \ cake memlimit 1b ping -I lo -f -c1 -s64 -W0.001 127.0.0.1 This is because the low memlimit leads to a low buffer_limit, which causes packet dropping. However, cake_enqueue still returns NET_XMIT_SUCCESS, causing htb_enqueue to call htb_activate with an empty child qdisc. We should return NET_XMIT_CN when packets are dropped from the same tin and flow. I do not believe return value of NET_XMIT_CN is necessary for packet drops in the case of ack filtering, as that is meant to optimize performance, not to signal congestion.

Gravité et risque d'exploitation

CVE-2025-39766 obtient un score CVSS de 0.0/10, soit une gravité non évaluée. Selon le modèle EPSS, la probabilité qu'elle soit exploitée dans les 30 prochains jours est de 0.18 %, ce qui la place devant 7.5 % des CVE référencées.

Que faire ?

  • Vérifiez si Linux (versions <=6.1.*, <de04ddd2980b48caa8d7e24a7db2742917a8b280, <=6.12.*, 6.12.44, <710866fc0a64eafcb8bacd91bcb1329eb7e5035f, <=6.16.*, 6.17, 0, <0dacfc5372e314d1219f03e64dde3ab495a5a25e, <7689ab22de36f8db19095f6bdf11f28cfde92f5c, 5.4.297, 6.6.103, 4.19, <=5.10.*, <=6.6.*, 5.15.190, <62d591dde4defb1333d202410609c4ddeae060b3, <=5.4.*, <aa12ee1c1bd260943fd6ab556d8635811c332eeb, <15de71d06a400f7fdc15bf377a2552b0ec437cf5, 6.1.149, <4.19, 5.10.241, <=*, 046f6fd5daefac7f5abdafb436b30f63bc7c602b, <=5.15.*, <ff57186b2cc39766672c4c0332323933e5faaa88, 6.16.4) est présent sur votre parc.
  • Appliquez le correctif ou la version corrigée indiqués dans les références de l'éditeur.
  • À défaut de correctif, limitez l'exposition (filtrage réseau, désactivation du composant).
  • Automatisez la détection : les agents CVE Heimdall (gratuits, open source) corrèlent l'inventaire de vos serveurs avec la base CVE.

Références