CVE-2025-59103

Vulnérabilité critique dans Access Manager 92xx-k5 (dormakaba)

CVSS 9.2 · Critique
EPSS 0.4%
dormakaba•Access Manager 92xx-k5•Versions : 92xx-K5: <BAME 05.01.88

Description

The Access Manager 92xx in hardware revision K7 is based on Linux instead of Windows CE embedded in older hardware revisions. In this new hardware revision it was noticed that an SSH service is exposed on port 22. By analyzing the firmware of the devices, it was noticed that there are two users with hardcoded and weak passwords that can be used to access the devices via SSH. The passwords can be also guessed very easily. The password of at least one user is set to a random value after the first deployment, with the restriction that the password is only randomized if the configured date is prior to 2022. Therefore, under certain circumstances, the passwords are not randomized. For example, if the clock is never set on the device, the battery of the clock module has been changed, the Access Manager has been factory reset and has not received a time yet.

Gravité et risque d'exploitation

CVE-2025-59103 obtient un score CVSS de 9.2/10, soit une gravité critique. Selon le modèle EPSS, la probabilité qu'elle soit exploitée dans les 30 prochains jours est de 0.42 %, ce qui la place devant 34.9 % des CVE référencées.

Que faire ?

  • Vérifiez si Access Manager 92xx-k5 (versions 92xx-K5: <BAME 05.01.88) est présent sur votre parc.
  • Appliquez le correctif ou la version corrigée indiqués dans les références de l'éditeur.
  • À défaut de correctif, limitez l'exposition (filtrage réseau, désactivation du composant).
  • Automatisez la détection : les agents CVE Heimdall (gratuits, open source) corrèlent l'inventaire de vos serveurs avec la base CVE.

Références