CVE-2026-17042
Vulnérabilité élevée dans Power Systems Firmware (IBM)
Description
IBM Power Systems Firmware FW950.00 through FW950.H2, OP940.00 through OP940.a1 (Power9), and OP940.00 - OP940.81 (Power HMC) is affected by a vulnerability in host firmware NVRAM parsing. An attacker with root access to a guest partition on an OpenPOWER system can write a specially crafted NVRAM image, causing the host firmware boot stage to crash with possible memory corruption. This condition persists until operator intervention — clearing NVRAM via the service processor — to restore normal operation. This vulnerability only affects OpenPOWER systems; systems running PowerVM are not affected. Successful exploitation results in an integrity and availability impact to the managed system.
Gravité et risque d'exploitation
CVE-2026-17042 obtient un score CVSS de 7.3/10, soit une gravité élevée. Selon le modèle EPSS, la probabilité qu'elle soit exploitée dans les 30 prochains jours est de 0.14 %, ce qui la place devant 3.0 % des CVE référencées.
Que faire ?
- Vérifiez si Power Systems Firmware (versions <=FW950.H2, <=OP940.a1, OP940.00, <=OP940.81, FW950.00) est présent sur votre parc.
- Appliquez le correctif ou la version corrigée indiqués dans les références de l'éditeur.
- À défaut de correctif, limitez l'exposition (filtrage réseau, désactivation du composant).
- Automatisez la détection : les agents CVE Heimdall (gratuits, open source) corrèlent l'inventaire de vos serveurs avec la base CVE.