CVE-2026-31428

Vulnérabilité non évaluée dans Linux (Linux)

CVSS 0.0 · Non évaluée
EPSS 0.2%
Linux•Linux•Versions : <=6.1.*, <=6.12.*, <a2f6ff3444b663d6cfa63eadd61327a18592885a, <7f3e5d72455936f42709116fabeca3bb216cda62, 0, df6fb868d6118686805c2fa566e213a8f31c8e4f, 7.0, <52025ebaa29f4eb4ed8bf92ce83a68f24ab7fdf7, <21d8efda029948d3666b0db5afcc0d36c0984aae, <c9f6c51d36482805ac3ffadb9663fe775a13e926, <=5.10.*, <=6.6.*, 6.19.11, <=6.19.*, 2.6.24, 5.15.203, <7eff72968161fb8ddb26113344de3b92fb7d7ef5, <=6.18.*, 6.6.131, 6.12.80, <a8365d1064ded323797c5e28e91070c52f44b76c, <=*, 5.10.253, <=5.15.*, 6.1.168, 6.18.21, <2.6.24, <fc961dd7272b5e4a462999635e44a4770d7f2482

Description

In the Linux kernel, the following vulnerability has been resolved: netfilter: nfnetlink_log: fix uninitialized padding leak in NFULA_PAYLOAD __build_packet_message() manually constructs the NFULA_PAYLOAD netlink attribute using skb_put() and skb_copy_bits(), bypassing the standard nla_reserve()/nla_put() helpers. While nla_total_size(data_len) bytes are allocated (including NLA alignment padding), only data_len bytes of actual packet data are copied. The trailing nla_padlen(data_len) bytes (1-3 when data_len is not 4-byte aligned) are never initialized, leaking stale heap contents to userspace via the NFLOG netlink socket. Replace the manual attribute construction with nla_reserve(), which handles the tailroom check, header setup, and padding zeroing via __nla_reserve(). The subsequent skb_copy_bits() fills in the payload data on top of the properly initialized attribute.

Gravité et risque d'exploitation

CVE-2026-31428 obtient un score CVSS de 0.0/10, soit une gravité non évaluée. Selon le modèle EPSS, la probabilité qu'elle soit exploitée dans les 30 prochains jours est de 0.18 %, ce qui la place devant 7.3 % des CVE référencées.

Que faire ?

  • Vérifiez si Linux (versions <=6.1.*, <=6.12.*, <a2f6ff3444b663d6cfa63eadd61327a18592885a, <7f3e5d72455936f42709116fabeca3bb216cda62, 0, df6fb868d6118686805c2fa566e213a8f31c8e4f, 7.0, <52025ebaa29f4eb4ed8bf92ce83a68f24ab7fdf7, <21d8efda029948d3666b0db5afcc0d36c0984aae, <c9f6c51d36482805ac3ffadb9663fe775a13e926, <=5.10.*, <=6.6.*, 6.19.11, <=6.19.*, 2.6.24, 5.15.203, <7eff72968161fb8ddb26113344de3b92fb7d7ef5, <=6.18.*, 6.6.131, 6.12.80, <a8365d1064ded323797c5e28e91070c52f44b76c, <=*, 5.10.253, <=5.15.*, 6.1.168, 6.18.21, <2.6.24, <fc961dd7272b5e4a462999635e44a4770d7f2482) est présent sur votre parc.
  • Appliquez le correctif ou la version corrigée indiqués dans les références de l'éditeur.
  • À défaut de correctif, limitez l'exposition (filtrage réseau, désactivation du composant).
  • Automatisez la détection : les agents CVE Heimdall (gratuits, open source) corrèlent l'inventaire de vos serveurs avec la base CVE.

Références