CVE-2026-31747

Vulnérabilité non évaluée dans Linux (Linux)

CVSS 0.0 · Non évaluée
EPSS 0.2%
Linux•Linux•Versions : <=6.1.*, <=6.12.*, <64b24b713e1a3ea6624480594b4f8c2ff86502f2, 3.19, 0, <3fb43a7a5b44713f892c58ead2e5f3a1bc9f4ee7, 6.6.134, 7.0, <de3f923ae7d91480ed3ecea1b1e1fc0dc25b597d, ac584af599452748187cf6d7865b1607c54ee443, <=5.10.*, <=6.6.*, <=6.19.*, <8ddfe6495c245226a30d8b36e2f4a7aa7712e8d6, 5.15.203, <=6.18.*, <eae19cab44204537f79146f15a51811b13227c38, 6.12.81, <=*, 5.10.253, <=5.15.*, <99f31aa98ab6e3805c455b65bcd01b3d48bdf1a5, 6.1.168, <3.19, <f72b5567f7c117b46b4058dc6a0c7554f8565561, <1603dd471f47762e9d1f52304edb3e49a7e62655, 6.18.22, 6.19.12

Description

In the Linux kernel, the following vulnerability has been resolved: comedi: me4000: Fix potential overrun of firmware buffer `me4000_xilinx_download()` loads the firmware that was requested by `request_firmware()`. It is possible for it to overrun the source buffer because it blindly trusts the file format. It reads a data stream length from the first 4 bytes into variable `file_length` and reads the data stream contents of length `file_length` from offset 16 onwards. Add a test to ensure that the supplied firmware is long enough to contain the header and the data stream. On failure, log an error and return `-EINVAL`. Note: The firmware loading was totally broken before commit ac584af59945 ("staging: comedi: me4000: fix firmware downloading"), but that is the most sensible target for this fix.

Gravité et risque d'exploitation

CVE-2026-31747 obtient un score CVSS de 0.0/10, soit une gravité non évaluée. Selon le modèle EPSS, la probabilité qu'elle soit exploitée dans les 30 prochains jours est de 0.18 %, ce qui la place devant 6.7 % des CVE référencées.

Que faire ?

  • Vérifiez si Linux (versions <=6.1.*, <=6.12.*, <64b24b713e1a3ea6624480594b4f8c2ff86502f2, 3.19, 0, <3fb43a7a5b44713f892c58ead2e5f3a1bc9f4ee7, 6.6.134, 7.0, <de3f923ae7d91480ed3ecea1b1e1fc0dc25b597d, ac584af599452748187cf6d7865b1607c54ee443, <=5.10.*, <=6.6.*, <=6.19.*, <8ddfe6495c245226a30d8b36e2f4a7aa7712e8d6, 5.15.203, <=6.18.*, <eae19cab44204537f79146f15a51811b13227c38, 6.12.81, <=*, 5.10.253, <=5.15.*, <99f31aa98ab6e3805c455b65bcd01b3d48bdf1a5, 6.1.168, <3.19, <f72b5567f7c117b46b4058dc6a0c7554f8565561, <1603dd471f47762e9d1f52304edb3e49a7e62655, 6.18.22, 6.19.12) est présent sur votre parc.
  • Appliquez le correctif ou la version corrigée indiqués dans les références de l'éditeur.
  • À défaut de correctif, limitez l'exposition (filtrage réseau, désactivation du composant).
  • Automatisez la détection : les agents CVE Heimdall (gratuits, open source) corrèlent l'inventaire de vos serveurs avec la base CVE.

Références