CVE-2026-45882

Vulnérabilité non évaluée dans Linux (Linux)

CVSS 0.0 · Non évaluée
EPSS 0.2%
Linux•Linux•Versions : <17db6b3abd823c9fba3f3413c4f0f432d99d49dc, 098bce1838e0549228c8d426e5de72ec5594b5c4, <a8b7117ae3a791c6a328674d05a06cd45d8241bd, <=6.12.*, <=*, <=6.18.*, <b69bb88e20c6f8e998dff3e13a316207f49d3fa2, 6.7, 0, <=6.19.*, 7.0, 6.18.14, <6.7, <62914959b35e9a1e29cc0f64cb8cfc5075a5366f, 6.12.75, 6.19.4

Description

In the Linux kernel, the following vulnerability has been resolved: power: supply: pm8916_bms_vm: Fix use-after-free in power_supply_changed() Using the `devm_` variant for requesting IRQ _before_ the `devm_` variant for allocating/registering the `power_supply` handle, means that the `power_supply` handle will be deallocated/unregistered _before_ the interrupt handler (since `devm_` naturally deallocates in reverse allocation order). This means that during removal, there is a race condition where an interrupt can fire just _after_ the `power_supply` handle has been freed, *but* just _before_ the corresponding unregistration of the IRQ handler has run. This will lead to the IRQ handler calling `power_supply_changed()` with a freed `power_supply` handle. Which usually crashes the system or otherwise silently corrupts the memory... Note that there is a similar situation which can also happen during `probe()`; the possibility of an interrupt firing _before_ registering the `power_supply` handle. This would then lead to the nasty situation of using the `power_supply` handle *uninitialized* in `power_supply_changed()`. Fix this racy use-after-free by making sure the IRQ is requested _after_ the registration of the `power_supply` handle.

Gravité et risque d'exploitation

CVE-2026-45882 obtient un score CVSS de 0.0/10, soit une gravité non évaluée. Selon le modèle EPSS, la probabilité qu'elle soit exploitée dans les 30 prochains jours est de 0.17 %, ce qui la place devant 6.0 % des CVE référencées.

Que faire ?

  • Vérifiez si Linux (versions <17db6b3abd823c9fba3f3413c4f0f432d99d49dc, 098bce1838e0549228c8d426e5de72ec5594b5c4, <a8b7117ae3a791c6a328674d05a06cd45d8241bd, <=6.12.*, <=*, <=6.18.*, <b69bb88e20c6f8e998dff3e13a316207f49d3fa2, 6.7, 0, <=6.19.*, 7.0, 6.18.14, <6.7, <62914959b35e9a1e29cc0f64cb8cfc5075a5366f, 6.12.75, 6.19.4) est présent sur votre parc.
  • Appliquez le correctif ou la version corrigée indiqués dans les références de l'éditeur.
  • À défaut de correctif, limitez l'exposition (filtrage réseau, désactivation du composant).
  • Automatisez la détection : les agents CVE Heimdall (gratuits, open source) corrèlent l'inventaire de vos serveurs avec la base CVE.

Références