CVE-2026-45968

Vulnérabilité non évaluée dans Linux (Linux)

CVSS 0.0 · Non évaluée
EPSS 0.1%
Linux•Linux•Versions : <=6.1.*, <=6.12.*, 0, 7.0, 6.1.165, 6.12.75, <a0724e40a58a0e323c59707edeae5b71d15800dc, <e5c9ffc6ae1bcdb1062527d611043681ac301aca, <=5.10.*, <=6.6.*, <=6.19.*, <8f6833d919bae915ead6c599a53e81e19b32da52, <5d103a38e2ae96eca57fd17161bcd29bd4622d1c, <a0f7e804edc82e513d1ccb7c95ed8b351522ec81, <=6.18.*, <4da2b897283c39980d6ae09dc1560fcd937879e5, <63ae78336f40bcd9a44952a7c6bafb9c88a8effd, 6.6.128, 5.10.252, dc2251bf98c66db3f4e055b751968f0871037ae4, 6.19.4, <=*, <4.14, <=5.15.*, <5c577ac939bca486cb02069505cfe47a5312ce02, 5.15.202, 4.14, 6.18.14

Description

In the Linux kernel, the following vulnerability has been resolved: cpuidle: Skip governor when only one idle state is available On certain platforms (PowerNV systems without a power-mgt DT node), cpuidle may register only a single idle state. In cases where that single state is a polling state (state 0), the ladder governor may incorrectly treat state 1 as the first usable state and pass an out-of-bounds index. This can lead to a NULL enter callback being invoked, ultimately resulting in a system crash. [ 13.342636] cpuidle-powernv : Only Snooze is available [ 13.351854] Faulting instruction address: 0x00000000 [ 13.376489] NIP [0000000000000000] 0x0 [ 13.378351] LR [c000000001e01974] cpuidle_enter_state+0x2c4/0x668 Fix this by adding a bail-out in cpuidle_select() that returns state 0 directly when state_count <= 1, bypassing the governor and keeping the tick running.

Gravité et risque d'exploitation

CVE-2026-45968 obtient un score CVSS de 0.0/10, soit une gravité non évaluée. Selon le modèle EPSS, la probabilité qu'elle soit exploitée dans les 30 prochains jours est de 0.13 %, ce qui la place devant 2.4 % des CVE référencées.

Que faire ?

  • Vérifiez si Linux (versions <=6.1.*, <=6.12.*, 0, 7.0, 6.1.165, 6.12.75, <a0724e40a58a0e323c59707edeae5b71d15800dc, <e5c9ffc6ae1bcdb1062527d611043681ac301aca, <=5.10.*, <=6.6.*, <=6.19.*, <8f6833d919bae915ead6c599a53e81e19b32da52, <5d103a38e2ae96eca57fd17161bcd29bd4622d1c, <a0f7e804edc82e513d1ccb7c95ed8b351522ec81, <=6.18.*, <4da2b897283c39980d6ae09dc1560fcd937879e5, <63ae78336f40bcd9a44952a7c6bafb9c88a8effd, 6.6.128, 5.10.252, dc2251bf98c66db3f4e055b751968f0871037ae4, 6.19.4, <=*, <4.14, <=5.15.*, <5c577ac939bca486cb02069505cfe47a5312ce02, 5.15.202, 4.14, 6.18.14) est présent sur votre parc.
  • Appliquez le correctif ou la version corrigée indiqués dans les références de l'éditeur.
  • À défaut de correctif, limitez l'exposition (filtrage réseau, désactivation du composant).
  • Automatisez la détection : les agents CVE Heimdall (gratuits, open source) corrèlent l'inventaire de vos serveurs avec la base CVE.

Références