CVE-2026-63889

Vulnérabilité élevée dans Linux (Linux)

CVSS 8.1 · Élevée
EPSS 0.4%
Linux•Linux•Versions : <5.11, <=6.1.*, <=7.0.*, <=6.12.*, 6.12.93, 0, 6.18.35, <ee57b89e5da9fffbe0d26647e4ff0750dacb9943, <07776b7779c9426982c1ad74aad91bd531593790, 5.11, <a9a39233ec1fc9f97ea1340a4d09bb7ec2be5153, 6.1.176, 5.15.210, <35461d23744175a78b6280293892cca357c22793, 3dcfe0de5a9752e646a61f4ce513ac059960c7c3, <=6.6.*, <bdff76dff6ec23d6fe35812fa33e5c4ce2cdb770, <29f126f09e34a425b376b3646c89aa7cc18b142c, 7.1, <=6.18.*, <163bd704d7515c3df6c2e03bcba93d1db79edbff, 7.0.12, <=*, <=5.15.*, 6.6.143

Description

In the Linux kernel, the following vulnerability has been resolved: scsi: scsi_transport_fc: Widen FPIN pname walker counter to u32 An adjacent Fibre Channel fabric actor that can deliver an FPIN ELS frame to an lpfc or qla2xxx Linux initiator can trigger a non-return in the generic FC transport. This is not a local userspace or IP network path; the attacker must be able to inject fabric traffic, for example as a compromised switch or fabric controller, or as a same-zone N_Port on a fabric that permits source spoofing. The Link-Integrity and Peer-Congestion FPIN walkers used a u8 loop counter against the 32-bit on-wire pname_count field, and did not bound pname_count by the descriptor body already validated by the TLV walker. A pname_count of 256 therefore wraps the counter and keeps the loop condition true indefinitely. Factor the shared pname_list[] walk into one helper, widen the counter to u32, and clamp pname_count against the entries that fit in the descriptor body before iterating.

Gravité et risque d'exploitation

CVE-2026-63889 obtient un score CVSS de 8.1/10, soit une gravité élevée. Selon le modèle EPSS, la probabilité qu'elle soit exploitée dans les 30 prochains jours est de 0.36 %, ce qui la place devant 28.1 % des CVE référencées.

Que faire ?

  • Vérifiez si Linux (versions <5.11, <=6.1.*, <=7.0.*, <=6.12.*, 6.12.93, 0, 6.18.35, <ee57b89e5da9fffbe0d26647e4ff0750dacb9943, <07776b7779c9426982c1ad74aad91bd531593790, 5.11, <a9a39233ec1fc9f97ea1340a4d09bb7ec2be5153, 6.1.176, 5.15.210, <35461d23744175a78b6280293892cca357c22793, 3dcfe0de5a9752e646a61f4ce513ac059960c7c3, <=6.6.*, <bdff76dff6ec23d6fe35812fa33e5c4ce2cdb770, <29f126f09e34a425b376b3646c89aa7cc18b142c, 7.1, <=6.18.*, <163bd704d7515c3df6c2e03bcba93d1db79edbff, 7.0.12, <=*, <=5.15.*, 6.6.143) est présent sur votre parc.
  • Appliquez le correctif ou la version corrigée indiqués dans les références de l'éditeur.
  • À défaut de correctif, limitez l'exposition (filtrage réseau, désactivation du composant).
  • Automatisez la détection : les agents CVE Heimdall (gratuits, open source) corrèlent l'inventaire de vos serveurs avec la base CVE.

Références