CVE-2026-74282

Vulnérabilité élevée dans Linux (Linux)

CVSS 7.5 · Élevée
EPSS 0.7%
Linux•Linux•Versions : 10724cc7bb7832b482df049c20fd824d928c5eaa, <=6.1.*, 7.1.5, 6.18.40, <=6.12.*, 0, <=7.1.*, <1e2c956745777e6ffdee7f30da5935741c03ee1e, 6.1.178, <ab3e10b44ba5411779aac7afd2477917dd77750f, <=5.10.*, <=6.6.*, 6.12.97, <96f91b8ae1a489b3eca137e7acf42cf985fb8939, <3cfa3d8e0dc167850edeb5bf5a07757db83fd54e, 4.7, <=6.18.*, 5.15.212, <3388145d258cf2c4c98278e3987296007d30672e, 6.6.145, 5.10.261, <67e55b054bf8025658dc0e255057f2a6236416bd, <=*, <=5.15.*, <4.7, <b44bebdd32c9ff66ee2aebfc317ced44bedd9335, 7.2, <47ed873e4ceda34098bd46d8e96b4bb13cad3a04

Description

In the Linux kernel, the following vulnerability has been resolved: tipc: prevent snt_unacked underflow on CONN_ACK tipc_sk_conn_proto_rcv() subtracts the peer-supplied connection ack count from the unsigned 16-bit send counter snt_unacked without checking that it does not exceed the number of messages actually outstanding: tsk->snt_unacked -= msg_conn_ack(hdr); msg_conn_ack() is read straight from a received CONN_MANAGER/CONN_ACK message. If the ack count is larger than snt_unacked, the subtraction wraps to a near-maximum value, leaving tsk_conn_cong() permanently true and starving the connection of further transmits. Validate the ACK count at the start of the CONN_ACK block and drop the message if it acknowledges more messages than are outstanding. A peer (or, for a local connection, the connected peer socket) can otherwise wedge a TIPC connection's send side by sending an oversized connection ack.

Gravité et risque d'exploitation

CVE-2026-74282 obtient un score CVSS de 7.5/10, soit une gravité élevée. Selon le modèle EPSS, la probabilité qu'elle soit exploitée dans les 30 prochains jours est de 0.70 %, ce qui la place devant 52.1 % des CVE référencées.

Que faire ?

  • Vérifiez si Linux (versions 10724cc7bb7832b482df049c20fd824d928c5eaa, <=6.1.*, 7.1.5, 6.18.40, <=6.12.*, 0, <=7.1.*, <1e2c956745777e6ffdee7f30da5935741c03ee1e, 6.1.178, <ab3e10b44ba5411779aac7afd2477917dd77750f, <=5.10.*, <=6.6.*, 6.12.97, <96f91b8ae1a489b3eca137e7acf42cf985fb8939, <3cfa3d8e0dc167850edeb5bf5a07757db83fd54e, 4.7, <=6.18.*, 5.15.212, <3388145d258cf2c4c98278e3987296007d30672e, 6.6.145, 5.10.261, <67e55b054bf8025658dc0e255057f2a6236416bd, <=*, <=5.15.*, <4.7, <b44bebdd32c9ff66ee2aebfc317ced44bedd9335, 7.2, <47ed873e4ceda34098bd46d8e96b4bb13cad3a04) est présent sur votre parc.
  • Appliquez le correctif ou la version corrigée indiqués dans les références de l'éditeur.
  • À défaut de correctif, limitez l'exposition (filtrage réseau, désactivation du composant).
  • Automatisez la détection : les agents CVE Heimdall (gratuits, open source) corrèlent l'inventaire de vos serveurs avec la base CVE.

Références