CVE-2026-74487

Vulnérabilité non évaluée dans Linux (Linux)

CVSS 0.0 · Non évaluée
EPSS 0.2%
Linux•Linux•Versions : <a50296cca2a1db9d8d21051e7d50f0cf3a4b7ec8, <=6.1.*, <=6.12.*, 5.15.217, 0, <7873f987213695e3564c8c259e6db283e4739472, <=7.1.*, <fdc1d702bf3001586221fa07e598e876a0a854c5, <dd9ba32169e73a3c3ba595cf1de1f4c69ceafb3c, <=5.10.*, <=6.6.*, 5.10.266, <13efc628fdf641d901bdba07caa1c558e1bed046, <=6.18.*, 6.1.184, 4.8, <=*, <3b522487a3a9162b1b519eefde7998d103e3e07b, <=5.15.*, <db1856ea9196cf6e015d12199a34c0b9313c7bfa, 6.6.153, 6.12.105, 7.1.8, <4.8, 6.18.44, <f1cf67f6be0babc73afa4ee0e27bdedffeeeb095, 948b701a607f123df92ed29084413e5dd8cda2ed, 7.2

Description

In the Linux kernel, the following vulnerability has been resolved: binfmt_misc: restore write access when removing an entry Registering an entry with the MISC_FMT_OPEN_FILE flag opens the interpreter via open_exec() which denies write access to it for as long as the entry exists. Removing the entry closes the interpreter file via filp_close() but never restores write access, leaving the inode's i_writecount permanently negative. Opening the interpreter for writing keeps failing with ETXTBSY long after the entry is gone until the inode is evicted from the inode cache. Commit 90f601b497d7 ("binfmt_misc: restore write access before closing files opened by open_exec()") fixed the same imbalance in the error path of bm_register_write() but the actual removal path has been leaking the write denial since the introduction of the flag. Restore write access in put_binfmt_handler() before closing the interpreter file.

Gravité et risque d'exploitation

CVE-2026-74487 obtient un score CVSS de 0.0/10, soit une gravité non évaluée. Selon le modèle EPSS, la probabilité qu'elle soit exploitée dans les 30 prochains jours est de 0.18 %, ce qui la place devant 6.8 % des CVE référencées.

Que faire ?

  • Vérifiez si Linux (versions <a50296cca2a1db9d8d21051e7d50f0cf3a4b7ec8, <=6.1.*, <=6.12.*, 5.15.217, 0, <7873f987213695e3564c8c259e6db283e4739472, <=7.1.*, <fdc1d702bf3001586221fa07e598e876a0a854c5, <dd9ba32169e73a3c3ba595cf1de1f4c69ceafb3c, <=5.10.*, <=6.6.*, 5.10.266, <13efc628fdf641d901bdba07caa1c558e1bed046, <=6.18.*, 6.1.184, 4.8, <=*, <3b522487a3a9162b1b519eefde7998d103e3e07b, <=5.15.*, <db1856ea9196cf6e015d12199a34c0b9313c7bfa, 6.6.153, 6.12.105, 7.1.8, <4.8, 6.18.44, <f1cf67f6be0babc73afa4ee0e27bdedffeeeb095, 948b701a607f123df92ed29084413e5dd8cda2ed, 7.2) est présent sur votre parc.
  • Appliquez le correctif ou la version corrigée indiqués dans les références de l'éditeur.
  • À défaut de correctif, limitez l'exposition (filtrage réseau, désactivation du composant).
  • Automatisez la détection : les agents CVE Heimdall (gratuits, open source) corrèlent l'inventaire de vos serveurs avec la base CVE.

Références