CVE-2026-7829

Vulnérabilité élevée dans UltraVNC (uvnc)

CVSS 7.2 · Élevée
EPSS 0.9%
uvnc•UltraVNC•Versions : <=1.8.2.2, 0

Description

UltraVNC repeater through 1.8.2.2 contains a post-authentication out-of-bounds write in the allow/deny rule parser. In repeater/webgui/settings.c:225-272, after strncpy_s copies a rule token into temp1[rule1] (25-byte destination) or temp2/temp3 (16-byte destination), the code unconditionally writes a NUL terminator at temp1[rule1][len] = 0 without clamping len to the destination size. When an authenticated administrator saves a rule with a token length equal to or greater than the destination size, the NUL byte is written one or more bytes past the end of the stack-allocated array, corrupting adjacent stack data. An attacker who has obtained admin credentials (including via CVE-2026-7839 default password) can trigger this to gain code execution on the repeater host.

Gravité et risque d'exploitation

CVE-2026-7829 obtient un score CVSS de 7.2/10, soit une gravité élevée. Selon le modèle EPSS, la probabilité qu'elle soit exploitée dans les 30 prochains jours est de 0.85 %, ce qui la place devant 57.5 % des CVE référencées.

Que faire ?

  • Vérifiez si UltraVNC (versions <=1.8.2.2, 0) est présent sur votre parc.
  • Appliquez le correctif ou la version corrigée indiqués dans les références de l'éditeur.
  • À défaut de correctif, limitez l'exposition (filtrage réseau, désactivation du composant).
  • Automatisez la détection : les agents CVE Heimdall (gratuits, open source) corrèlent l'inventaire de vos serveurs avec la base CVE.

Références