CVE-2026-7831
Vulnérabilité élevée dans UltraVNC (uvnc)
Description
UltraVNC viewer through 1.8.2.2 contains an off-by-one stack buffer overflow in the RFB ServerInit message handler. In vncviewer/ClientConnection.cpp, when the server-supplied nameLength equals exactly 2024 the code declares a 2024-byte stack buffer _dn[2024] and calls ReadString(_dn, 2024). ReadString writes the NUL terminator at buf[length], i.e., _dn[2024], one byte past the end of the stack buffer. A malicious VNC server can trigger this condition by advertising a desktop name of length 2024 in its ServerInit message. On release builds without stack canaries the single-byte NUL overwrite adjacent stack data. On builds with /GS stack protection the canary is corrupted and the process terminates, resulting in denial of service. User interaction (connecting the viewer to the malicious server) is required.
Gravité et risque d'exploitation
CVE-2026-7831 obtient un score CVSS de 7.5/10, soit une gravité élevée. Selon le modèle EPSS, la probabilité qu'elle soit exploitée dans les 30 prochains jours est de 0.74 %, ce qui la place devant 53.7 % des CVE référencées.
Que faire ?
- Vérifiez si UltraVNC (versions <=1.8.2.2, 0) est présent sur votre parc.
- Appliquez le correctif ou la version corrigée indiqués dans les références de l'éditeur.
- À défaut de correctif, limitez l'exposition (filtrage réseau, désactivation du composant).
- Automatisez la détection : les agents CVE Heimdall (gratuits, open source) corrèlent l'inventaire de vos serveurs avec la base CVE.