CVE-2026-89747

Vulnérabilité élevée dans Linux (Linux)

CVSS 7.8 · Élevée
EPSS 0.2%
Linux•Linux•Versions : <05ebe1e1d7d38c2612bacfefe043a33572ae34cb, 6.8, <=*, <=6.12.*, <6.8, f9b94daa542a8d2532f0930f01cd9aec2d19621b, <=6.18.*, <7a49d19ff9baaf61217e5ec14199c18bc2d93ee4, 6.18.50, 0, <372f8534244d632ad5118e8a87a11291b01712d3, <=7.2.*, 6.12.109, 7.2.4, <ddbe921ed16a0ad2d9e09574c3f3aabec7528325, 7.3

Description

In the Linux kernel, the following vulnerability has been resolved: tracing: Fix use-after-free in trace_pipe read on sub-buffer order change Writing to buffer_subbuf_size_kb calls ring_buffer_subbuf_order_set(), which frees every sub-buffer of the ring buffer, including the reader page, and replaces them with newly allocated ones. Readers of trace_pipe hold pointers into those pages. ring_buffer_peek() looks up an event under cpu_buffer->reader_lock but returns the event pointer after dropping the lock, and peek_next_entry() then calls ring_buffer_event_length() and ring_buffer_event_data() on it. If the sub-buffer order is changed in that window, the reader dereferences freed memory: BUG: KASAN: use-after-free in ring_buffer_peek+0x3e0/0x430 Read of size 1 at addr ffff88802a4cf010 by task syz-executor989/6002 Freed by: free_buffer_page kernel/trace/ring_buffer.c:398 [inline] ring_buffer_subbuf_order_set+0x1325/0x18e0 kernel/trace/ring_buffer.c:7444 buffer_subbuf_size_write+0x182/0x280 kernel/trace/trace.c:8221 Take trace_access_lock(RING_BUFFER_ALL_CPUS) around the order change. This is the lock trace_pipe readers already hold across their entire peek-and-print loop, so the swap can no longer race with a reader that is dereferencing a peeked event.

Gravité et risque d'exploitation

CVE-2026-89747 obtient un score CVSS de 7.8/10, soit une gravité élevée. Selon le modèle EPSS, la probabilité qu'elle soit exploitée dans les 30 prochains jours est de 0.16 %, ce qui la place devant 5.2 % des CVE référencées.

Que faire ?

  • Vérifiez si Linux (versions <05ebe1e1d7d38c2612bacfefe043a33572ae34cb, 6.8, <=*, <=6.12.*, <6.8, f9b94daa542a8d2532f0930f01cd9aec2d19621b, <=6.18.*, <7a49d19ff9baaf61217e5ec14199c18bc2d93ee4, 6.18.50, 0, <372f8534244d632ad5118e8a87a11291b01712d3, <=7.2.*, 6.12.109, 7.2.4, <ddbe921ed16a0ad2d9e09574c3f3aabec7528325, 7.3) est présent sur votre parc.
  • Appliquez le correctif ou la version corrigée indiqués dans les références de l'éditeur.
  • À défaut de correctif, limitez l'exposition (filtrage réseau, désactivation du composant).
  • Automatisez la détection : les agents CVE Heimdall (gratuits, open source) corrèlent l'inventaire de vos serveurs avec la base CVE.

Références