CVE-2026-90100

Vulnérabilité non évaluée dans Linux (Linux)

CVSS 0.0 · Non évaluée
EPSS 0.2%
Linux•Linux•Versions : 6.18.52, <08988d1941e180f0ad30d91233cb64f3418ba23c, 7.2.6, <=*, <777dbc9914b2f003f1d44af80c7a4a395c5961b2, 6.18, <=6.18.*, 0, 671e266835b8a87d6cc2c6db962de23783405dd8, <=7.2.*, <6.18, <51fe3fe0ffec033bd831c71d9bee3dee827e491c, 7.3

Description

In the Linux kernel, the following vulnerability has been resolved: ptp: netc: fix period truncation and potential divide-by-zero in PEROUT The max_period bound in net_timer_enable_perout() was computed as: max_period = (u64)NETC_TMR_DEFAULT_FIPER + integral_period; which exceeds U32_MAX when integral_period > 0 (e.g. 0x100000002 for the default 333333333 Hz clock). A period_ns that passes this check but exceeds U32_MAX is then silently truncated when stored into the u32 struct netc_pp::period field. A truncated value of zero can reach netc_timer_set_perout_alarm(), where the local u32 period variable would also be 0, causing a divide-by-zero in roundup_u64(delta, period) whenever the stime < min_time branch is taken (which always happens for a start time of {0, 0}). Additionally, netc_timer_enable_periodic_pulse() and netc_timer_enable_fiper() both compute: fiper = pp->period - integral_period; A zero pp->period results in an unsigned wraparound to 0xFFFFFFFD, mis-programming the FIPER hardware register. Fix all three issues by capping max_period at NETC_TMR_DEFAULT_FIPER (0xFFFFFFFF). This ensures that any period_ns passing the range check fits in a u32 without truncation, so the stored value is always valid and non-zero. The accepted range is reduced by integral_period ns (typically only a few nanoseconds), which is negligible in practice.

Gravité et risque d'exploitation

CVE-2026-90100 obtient un score CVSS de 0.0/10, soit une gravité non évaluée. Selon le modèle EPSS, la probabilité qu'elle soit exploitée dans les 30 prochains jours est de 0.21 %, ce qui la place devant 10.1 % des CVE référencées.

Que faire ?

  • Vérifiez si Linux (versions 6.18.52, <08988d1941e180f0ad30d91233cb64f3418ba23c, 7.2.6, <=*, <777dbc9914b2f003f1d44af80c7a4a395c5961b2, 6.18, <=6.18.*, 0, 671e266835b8a87d6cc2c6db962de23783405dd8, <=7.2.*, <6.18, <51fe3fe0ffec033bd831c71d9bee3dee827e491c, 7.3) est présent sur votre parc.
  • Appliquez le correctif ou la version corrigée indiqués dans les références de l'éditeur.
  • À défaut de correctif, limitez l'exposition (filtrage réseau, désactivation du composant).
  • Automatisez la détection : les agents CVE Heimdall (gratuits, open source) corrèlent l'inventaire de vos serveurs avec la base CVE.

Références