CVE-2026-90255

Vulnérabilité élevée dans Linux (Linux)

CVSS 8.8 · Élevée
EPSS 0.3%
Linux•Linux•Versions : <=6.1.*, <=6.12.*, 0, 6.1.188, e07a06b4eb417f5271d33ce2240e93c62d98b7b4, 6.18.52, <=6.6.*, <c1fe3c74a89a7749cba3caa0dd91236049c66116, 6.6.157, 7.2.6, <9a2ba69cebe3fc5a3d4fa8eaaad3c42862723c27, <42de40abe25db9211107af8896d0fd741f10648d, <4d7b1c834d2775b73c65e4888e01f5af8b477fe9, <=6.18.*, <a661de0ee29d0915c5e924edf91d2be2b4d35bae, 6.12.110, 6.1, <=7.2.*, <37cfec41365c826d5496ef5d00c9e215eee53aa2, <=*, <6.1, 7.3

Description

In the Linux kernel, the following vulnerability has been resolved: Bluetooth: hci_conn: fix the SCO setup context lifetime hci_setup_sync() queues a conn_handle_t with a NULL destroy callback, so the context is only freed if hci_enhanced_setup_sync() actually runs. An entry that is cancelled instead is leaked, as _hci_cmd_sync_cancel_entry() does not release entry->data when there is no destroy callback, and hci_cmd_sync_clear() cancels every pending entry when the controller is unregistered. The context also stores a bare hci_conn pointer, so the connection can be freed while the work is queued. The dequeue in hci_conn_del() does not cover it either, as it matches on entry->data == conn and entry->data is the wrapper here. Same problem as commit 2f5d635ad590 ("Bluetooth: hci_sync: hold conn in hci_connect_acl/le_sync() callbacks"). Hold the connection and release both from a destroy callback. The submission failure path drops both, since hci_cmd_sync_submit() does not call the destroy callback when it fails to queue.

Gravité et risque d'exploitation

CVE-2026-90255 obtient un score CVSS de 8.8/10, soit une gravité élevée. Selon le modèle EPSS, la probabilité qu'elle soit exploitée dans les 30 prochains jours est de 0.34 %, ce qui la place devant 26.0 % des CVE référencées.

Que faire ?

  • Vérifiez si Linux (versions <=6.1.*, <=6.12.*, 0, 6.1.188, e07a06b4eb417f5271d33ce2240e93c62d98b7b4, 6.18.52, <=6.6.*, <c1fe3c74a89a7749cba3caa0dd91236049c66116, 6.6.157, 7.2.6, <9a2ba69cebe3fc5a3d4fa8eaaad3c42862723c27, <42de40abe25db9211107af8896d0fd741f10648d, <4d7b1c834d2775b73c65e4888e01f5af8b477fe9, <=6.18.*, <a661de0ee29d0915c5e924edf91d2be2b4d35bae, 6.12.110, 6.1, <=7.2.*, <37cfec41365c826d5496ef5d00c9e215eee53aa2, <=*, <6.1, 7.3) est présent sur votre parc.
  • Appliquez le correctif ou la version corrigée indiqués dans les références de l'éditeur.
  • À défaut de correctif, limitez l'exposition (filtrage réseau, désactivation du composant).
  • Automatisez la détection : les agents CVE Heimdall (gratuits, open source) corrèlent l'inventaire de vos serveurs avec la base CVE.

Références