CVE-2026-97482

Vulnérabilité non évaluée dans Linux (Linux)

CVSS 0.0 · Non évaluée
EPSS 0.2%
Linux•Linux•Versions : <=6.1.*, <=6.12.*, 2.6.12, 6.18.53, 0, <28d78783a871cdb7a637dcb72452ff7d303430ae, <2.6.12, 1da177e4c3f41524e886b7f1b8a0c1fc7321cac2, 5.10.271, 6.6.158, <=5.10.*, <=6.6.*, 6.1.189, <d7b33afbf9b54b61cb423af9663df54eae11d3b1, <a018d4195114ca2cf79858cc45c98581dee4795b, <=6.18.*, 5.15.222, <10d7fc3008d5b7ec03af8e08927f1d090014c2af, <5bf5e3fba9bc7dfd69701521dbe9809f8ccbdb02, <=*, <999ff3bf665f2abfb6af519ef3d6d42b061d3c15, <=5.15.*, <ea2901a4a90afc662e4d023542d91f10ab10fd3c, 7.2, 6.12.111

Description

In the Linux kernel, the following vulnerability has been resolved: usb: gadget: goku_udc: avoid NULL deref of dev->driver in INT_USBRESET log goku_irq() handles a number of bus events under a single ep0 path. It already guards the gadget driver suspend/resume callbacks against a NULL ->driver: if (dev->gadget.speed != USB_SPEED_UNKNOWN && dev->driver && dev->driver->resume) { spin_unlock(&dev->lock); dev->driver->resume(&dev->gadget); ... } but the very next branch unconditionally dereferences dev->driver when an INT_USBRESET arrives: if (stat & INT_USBRESET) { ACK(INT_USBRESET); INFO(dev, "USB reset done, gadget %s\n", dev->driver->driver.name); } If the controller raises INT_USBRESET before any gadget driver has been bound (or after one has been unbound), dev->driver is NULL and the printk dereferences NULL. smatch flags the inconsistency: drivers/usb/gadget/udc/goku_udc.c:1618 goku_irq() error: we previously assumed 'dev->driver' could be null (see line 1607) Fall back to a placeholder when the gadget driver is not bound. No functional change while a gadget driver is bound.

Gravité et risque d'exploitation

CVE-2026-97482 obtient un score CVSS de 0.0/10, soit une gravité non évaluée. Selon le modèle EPSS, la probabilité qu'elle soit exploitée dans les 30 prochains jours est de 0.17 %, ce qui la place devant 6.2 % des CVE référencées.

Que faire ?

  • Vérifiez si Linux (versions <=6.1.*, <=6.12.*, 2.6.12, 6.18.53, 0, <28d78783a871cdb7a637dcb72452ff7d303430ae, <2.6.12, 1da177e4c3f41524e886b7f1b8a0c1fc7321cac2, 5.10.271, 6.6.158, <=5.10.*, <=6.6.*, 6.1.189, <d7b33afbf9b54b61cb423af9663df54eae11d3b1, <a018d4195114ca2cf79858cc45c98581dee4795b, <=6.18.*, 5.15.222, <10d7fc3008d5b7ec03af8e08927f1d090014c2af, <5bf5e3fba9bc7dfd69701521dbe9809f8ccbdb02, <=*, <999ff3bf665f2abfb6af519ef3d6d42b061d3c15, <=5.15.*, <ea2901a4a90afc662e4d023542d91f10ab10fd3c, 7.2, 6.12.111) est présent sur votre parc.
  • Appliquez le correctif ou la version corrigée indiqués dans les références de l'éditeur.
  • À défaut de correctif, limitez l'exposition (filtrage réseau, désactivation du composant).
  • Automatisez la détection : les agents CVE Heimdall (gratuits, open source) corrèlent l'inventaire de vos serveurs avec la base CVE.

Références