CVE-2026-97558

Vulnérabilité non évaluée dans Linux (Linux)

CVSS 0.0 · Non évaluée
EPSS 0.2%
Linux•Linux•Versions : <=*, <=6.12.*, 5.13, 7.2.7, <a6767712902beb0f53238be485971c9a83ea1079, <5.13, <=6.18.*, <bbeb7a42c9ea656e17ddcbdc2d7917aa853383a6, 6.18.54, <5520e89a5a4f834bced64cf2ac927001cc513a40, 7.3, 0, <=7.2.*, <ea93759d6c2789924f4e557aed5be532207715ea, c3f207ab29f793b8c942ce8067ed123f18d5b81b, 6.12.113

Description

In the Linux kernel, the following vulnerability has been resolved: smb: client: fix cifsFileInfo reference leak in deferred close When cifs_close() defers a close, it hands the cifsFileInfo reference of the closing struct file to the queued work. Each execution of smb2_deferred_work_close() drops one such reference. deferred_close_scheduled can be false while the work is pending: the workqueue clears PENDING when the callback starts to run, before the callback clears the flag under deferred_lock. A close in that interval requeues the running work, and the callback then clears the flag, leaving the requeued work pending with the flag down. A later cifs_open() can reuse the handle and its cifs_close() reaches the same branch: queue_delayed_work() fails because the work is still pending, but cifs_close() returns without dropping the closing file's reference. The cifsFileInfo count stays pinned and its tlink, dentry and server handle are leaked. Check the return value and hand off the reference only when work was actually queued. Otherwise, use the shared _cifsFileInfo_put(), like the mod_delayed_work() branch above: the pending execution already owns its reference. This issue was found by an in-house static analysis tool.

Gravité et risque d'exploitation

CVE-2026-97558 obtient un score CVSS de 0.0/10, soit une gravité non évaluée. Selon le modèle EPSS, la probabilité qu'elle soit exploitée dans les 30 prochains jours est de 0.21 %, ce qui la place devant 11.1 % des CVE référencées.

Que faire ?

  • Vérifiez si Linux (versions <=*, <=6.12.*, 5.13, 7.2.7, <a6767712902beb0f53238be485971c9a83ea1079, <5.13, <=6.18.*, <bbeb7a42c9ea656e17ddcbdc2d7917aa853383a6, 6.18.54, <5520e89a5a4f834bced64cf2ac927001cc513a40, 7.3, 0, <=7.2.*, <ea93759d6c2789924f4e557aed5be532207715ea, c3f207ab29f793b8c942ce8067ed123f18d5b81b, 6.12.113) est présent sur votre parc.
  • Appliquez le correctif ou la version corrigée indiqués dans les références de l'éditeur.
  • À défaut de correctif, limitez l'exposition (filtrage réseau, désactivation du composant).
  • Automatisez la détection : les agents CVE Heimdall (gratuits, open source) corrèlent l'inventaire de vos serveurs avec la base CVE.

Références